SPECIFICATIONS

 

• Rated voltage: 36V /43V /48DC

 

• Rated current: 10mA

 

• Maximum operating current: 30mA

 

• Power-off leakage current: ≤1uA

 

• Operating current which supplied to control-

ler:  50mA

 

• Operation temperature: -20

~45

 

• Storage temperature: -30

~70

 

• IP level: IP65

 

• Storage ambient humidity: 30%-70%

Содержание DP C15.UART

Страница 1: ...AL DP C15 UART CONTENT Content 1 Introduction 2 Specifications 3 Functions overview 4 Normal indication area 5 Button definition 6 Normal operation 7 Functions setting 8 Error code definition 11 DP C1...

Страница 2: ...C15 U BAFANG display model 1 1 Hardware version number B Second line as below 602P1R3230002 602 Wire length and connector type 850 M5 2 P1 Internal identify number R3230002 Production date is 23th Mar...

Страница 3: ...Rated voltage 36V 43V 48DC Rated current 10mA Maximum operating current 30mA Power off leakage current 1uA Operating current which supplied to control ler 50mA Operation temperature 20 45 Storage temp...

Страница 4: ...e indication for single riding Trip indication including single trip distance total distance and remaining distance Control and indication for push assistance Control and indication for the headlight...

Страница 5: ...pacity Multiply function indication It consists of single trip distance TRIP total distance ODO remaining distance RANGE output power POWER energy consumption Cal riding time TIME Note Within ten seco...

Страница 6: ...urn off the headlight Turn on the light When the headlight is off and press and hold the button the luminance of the display backlight will decrease and the icon of the headlight will be showed Turn o...

Страница 7: ...peed RANGE remaining distance CALO RIES CAL KCal TIME riding time POWER output power TRIP single trip distance Error code indication When the failure occurs the display will show the error code and th...

Страница 8: ...resetting the single trip distance it resets the riding time average speed maximum speed at the same time YES means resetting NO means no resetting Unit switch between Metric and Impe rial Enter into...

Страница 9: ...tion interface Press and hold and at the same time to exit back to main interface or select BACK EXIT to exit back main interface Wheel size indication interface Check speed limit Enter into Informati...

Страница 10: ...ime h d00 Number of bat tery cell d01 Voltage of cell 1 mV d02 Voltage of cell 2 mV mV dn Voltage of cell n mV Check history of error codes Enter into Information interface and briefly press or to sel...

Страница 11: ...specialist to have the error fixed 21 Fault with wheel speed detecting sensor Bring your Pedelec to your dealer or to a specialist to have the error fixed 22 BMS communication fault Bring your Pedele...

Страница 12: ...12 DISPLAY MANUAL DP C15 UART NOTES...