Chapter 2 Safety Precautions for the User 

Safety Precautions for the User 

Aircraft safety 

Cellular  engines  can  interfere  with  an  aircraft’s  navigation  system  and  its 
cellular network. The use of UniMod GSM-3+ on board aircraft is forbidden 
by  law.  Failure  to  comply  with  this  prohibition  may  lead  to  temporary 
suspension  or  permanent  cancellation  of  cellular  engine  services  for  the 
person  who  infringes  this  prohibition  and/or  to  legal  action  against  said 
person. 

Environments with explosive substances 

a) Users are advised not to use the device in automotive service stations. 
b) Users are reminded of the necessity to comply with restrictions regarding 
the  use  of  radio  devices  in  fuel  depots,  chemicals  plants  and  locations 
where explosives are ignited. 

Non-ionising radiation 

As is the case with other mobile radio transmitters, operating personnel are 
advised to use the device in the normal operating position only in order to 
ensure optimum performance and safety. Avoid touching the antenna. 

Personnel 

Installation and repairing should be done by experienced personnel only. 

Connecting to other devices 

In order to connect the UniMod GSM-3+ to another device please read the 
device’s operation manual to obtain detailed information about safety. Don’t 
connect devices, which are not approved by manufacturer. 

Precautions in the event of loss/theft of the Cellular Engine and 
the SIM card 

If  your  UniMod  GSM-3+,  your  SIM  card  or  both  go  missing,  notify  your 
network operator immediately in order to avoid misuse. 
 

Содержание UniMod GSM-3+

Страница 1: ...UniMod GSM 3 Modem Operation Manual E1300107207063 B r Industrie Elektronik GmbH Rathsbergstr 23 D 90411 N rnberg Germany Phone 49 911 970590 Fax 49 911 9705950 Internet www baer gmbh com...

Страница 2: ...mbH preserve the right to modify and improve the software product described in this document Specifications and other information contained in this document can change without prior notice This docume...

Страница 3: ...Hints 11 7 Programming the Modem 12 7 1 Testing the connection 17 7 2 Unusual reaction using 7 data bits and Even Parity during data retrieval 17 8 Additional Functions 18 8 1 Reset 18 8 2 Signal Qual...

Страница 4: ...UniMod GSM 3 4...

Страница 5: ...3 can be used in any GSM 900 1800 1900 MHz network with an arbitrary number of providers It requires however the infrastructure for operating mobile stations with 2 Watt EGSM900 or 1 Watt GSM1800 190...

Страница 6: ...garding the use of radio devices in fuel depots chemicals plants and locations where explosives are ignited Non ionising radiation As is the case with other mobile radio transmitters operating personn...

Страница 7: ...to operate on a wide range AC or DC supply voltage 80VAC to 270VAC 50 60Hz or 60VDC to 375VDC Alternative 12VDC to 15VDC 0 8A Attention NEVER remove the interface modules or the SIM card when the dev...

Страница 8: ...enabled via jumpers tp and tn This interface supports echo suppression and can be operated without load terminal open 1 2 0 R Y Z R I RS232 RxD TxD DTR DCD DSR RI GND external cables RTS and CTS can b...

Страница 9: ...C T S t m R T S RS485 2 wires t p C T S t m R T S RS485 4 wires When the 4 wire interface is used the internal 20mA interface must de deactivated Set jumper CTS and RTS instead of tp and tm t p C T S...

Страница 10: ...the network monitoring control channels and user interactions no call in progress permanently on CSD call Connection to remote party INF Information 3 LEDs showing processor status and field strength...

Страница 11: ...ide in the arrow s direction OPEN After release you can open the lid and insert the SIM card as shown in the picture Please note the position of the bevelled edge it must point at the lower right side...

Страница 12: ...determines whether or not the modem echoes characters received from PC during command state 0 no echo Q0 V0 Information response numeric code IPR 19200 Internal baud rate don t change this value CBST...

Страница 13: ...ter instead of the interface module The notch must point in direction of the modem module 4 After programming switch off the UniMod and insert the interface module carefully again Now you have to set...

Страница 14: ...1 CLIP 0 2 CAOC 0 COPS 0 0 E Plus CGSMS 3 Inquires current configuration ati SIEMENS MC55 REVISION xx xx Requests product information at cpin code OK SIM card inquiry code ERROR no faulty SIM card cod...

Страница 15: ...sec V 32 asynchronous mode non transparent at f OK Set all parameters to factory defaults ats0 n OK This parameter setting determines the number of rings 0 to 255 before automatic answering e g ats0 1...

Страница 16: ...itch on UniMod GSM 3 wait 15 to 30 sec till first LED is on Start the UniModSet software Read the equipment configuration Adjust the parameter Hint Mind to set the functionality of the internal RS485...

Страница 17: ...l has been transmitted via voice mode Call rejected by modem CRING FAX incoming call has been transmitted via fax mode Call rejected by modem 7 2 Unusual reaction using 7 data bits and Even Parity dur...

Страница 18: ...5 Z Keep tp and tm open in this case pc2 Must be open always used for internal processing eep Closed Allow programming changing of parameters by UniModSet program allowed Open parameter memory EEPROM...

Страница 19: ...Encoding see table below LED on LED off INF LED Signal level Description 99dBm to 113dBm Bad signal quality transmission may be disturbed 83dBm to 97dBm Low signal quality 67dBm to 81dBm Medium signa...

Страница 20: ...ers and SMS input contact 80 270 VAC 60 375 VDC SMS 20mA GSM 900 1800 GPRS XXXXXXX XXXXXXX 1 8 7 6 5 4 3 2 GSM RJ48 8 9 UniMod GSM 3 Interface RS232 Baudrate 9600 8n1 80VAC 270VAC 50 60Hz 60VDC 375VDC...

Страница 21: ...g different baud rates between 300 and 19200 Bd When the meter answers the successful baud rate is saved This baud rate is the restored after each power outage or processor reset In order to use AutoB...

Страница 22: ...times 19200 Baud Operating status after baud rate detection In GPRS mode a warm restart is done Meter can be read after 30 seconds In CSD mode dial up connection the modem pauses for 10 seconds After...

Страница 23: ...UniMod GSM 3 Chapter 8 Additional Functions 23 You can enable disable the AutoBaud functionality using function auto baud rate IEC 62056 21 1107 local in the UniMod Set program See below...

Страница 24: ...first number x defines the baud rate the second one y the data format The modem switches after the character is recognized without acknowledgement These parameters are possible x 0 300 Baud 1 600 Bau...

Страница 25: ...M Bus active can supply 10 devices max Service interface RS232 RxD TxD GND DTR DCD RTS and CTS bridged SMS input UE 12VDC in place of DTR signal for potential free contact Display LED s Power GSM 3 I...

Страница 26: ...module as ordered Standard antenna length of cable about 2 6m Operation manual Accessories RS232 cable 4301 or adapter for parametering 9177 Antenna for special purposes Additional interface modules S...

Страница 27: ...les When inserting the interface modules their component side must be at the left side and wired according the picture In the following sketch the components are at the left side RS232 20mA active 20m...

Страница 28: ...48 Interfaces 20mA active on Board CTS RTS RxD TxD tp tm B A Y Z B A GND RJ48 1 A A RxD Y A TxD DCD UA Z B DTR UE GND GND B B 2 3 4 5 7 6 8 9 10 1 10 RS232 RS485 4 wire RS485 2 wire SMS RJ48 10 1 Opti...

Страница 29: ...UniMod GSM 3 29...

Страница 30: ...UniMod GSM 3 SUBJECT TO CHANGE WITHOUT NOTICE...

Отзывы: