Badger Power Electronics
2
.9 NTC/RMO/DRY Connection(s)
9-Pins Terminal Configuration of Auxiliary Communication
PIN
Function Description
1
2
3
4
5
6
7
8
9
NO1 (Normal Open)
N1
N2
NC1 (Normal Close)
NC2 (Normal Close)
NC2 (Normal Close)
REMO OFF
GND S (NTC BAT)
NTC BAT+
1 2 3 4 5 6 7 8
9
Pin123456789
NTC
RMO
DRY
9
8
7
6
5
4
3
2
1
Pin Function
1
2
3
4
5
6
7
8
9
Insert its 9-Pins terminal into the corresponding NTC/RMO/DRY port on the ESS inverter.
Install the seal into the threaded sleeve, fasten the rubber nut and screw the waterproof cover back
to inverter firmly with 4 x M4 screws; 1.2N.m.
cc
G S L H
1
2
3
4
5
6
7
8
9
Rubber nut
Threaded
sleeve
NTC/RMO/
DRY cable(s)
Waterproof cover
Seal
Inverter
side
Don’t cut off any
communication cables.
Unscrew the waterproof cover
and loosen the rubber nut on
waterproof cover.
Make the 9-Pins terminal according to above function description of each Pin definition
for the auxiliary port you want to use.
Lead the NTC/RMO/DRY cable(s) through the rubber nut, seal and waterproof cover in turn.
Press the NTC/RMO/DRY cable(s)
in the seal via the side incisions.
NTC/RMO/DRY
Control Module(s)
9-Pins
terminal