background image

Installation & Operation Manual

10-PTT-UM-00311 (August 2012)

PFA Ellipse

Fire Pump System

Badger Meter

®

FLO

W M

ETE

RS

DEB

ITM

ETE

RS

MED

IDO

R D

E F

LUJ

O

F M

APPR

OVED

F M

APPROVED

PFA-XXX

X inch

250 SWP

X/XX

S/N AXXXXXXX

1000

1500

2000

2500 GPM

3000

3500

4000

Содержание PRESO Ellipse PFA Series

Страница 1: ...anual 10 PTT UM 00311 August 2012 PFA Ellipse Fire Pump System Badger Meter FLOW METERS DEBITMETERS MEDIDOR DE FLUJO F M APP RO VE D F M APPROVED PFA XXX X inch 250 SWP X XX S N AXXXXXXX 1000 1500 2000 2500 GPM 3000 3500 4000 ...

Страница 2: ... comes with instru ment shut off valves with provisions to accept a direct indicating meter II SPECIFICATIONS Applications Liquids Pipe Sizes 2 to 16 inches 50 to 406 4 mm Pressure 400 PSI 2758 kPa maximum Temperature Gage PFA Velocity Sensor 180 F 80 C maximum 250 F 121 C maximum Accuracy 1 75 of reading Turndown Ratio 17 1 with no vacuum effect Standard Components Y type head brass Compression f...

Страница 3: ...F M APPROVED FIGURE 1 HORIZONTAL PIPE INSTALLATION LIQUID F L O W M E T E R S D E B IT M E T E R S M E D ID O R D E F L U J O F M A P P R O V ED F L O W FIELD WELD H L FLOW METERS DEBIT METERS MEDID OR DE FLUJO F M APPROVED F L O W FIELD WELD H L FIGURE 2 VERTICAL PIPE INSTALLATION NOTE Pipe must remain full at all times during measurements NOTE Pipe must remain full at all times during measuremen...

Страница 4: ... 6 12 PFA 1 11 14 16 PFA 1 1 13 TABLE 1 SINGLE SUPPORT DRILL BIT SIZE 6 Install the supplied compression fitting by threading it into the weld o let manually Then with a wrench tighten the fitting a further 1 turns taking care not to tighten the compression nut 7 Install the instrument valves at the PFA Ellipse head connections Ensure that the valves are FULLY CLOSED to prevent them from leaking d...

Страница 5: ...A Ellipse sensor through the two holes Make sure that the double support pin passes through the guide ring See Figure 5 4 Align the arrow located on the sensor head in the direction of flow as in Step 9 Section IV 5 Ensure that the PFA Ellipse is in the correct orientation and spans the inside of the pipe Tighten the compression nut After tightening the compression nut manually tighten it 1 turns ...

Страница 6: ...FLUJO F M APP RO VE D FLOW FIELD WELD H L H L FIGURE 4 SENSOR ALIGNMENT PIPE SIZE MODEL SENSOR WELD CONNECTOR DRILL BIT 2 5 PFA 1 3 6 12 PFA 14 16 PFA 1 1 TABLE 2 DOUBLE SUPPORT DRILL BIT SIZE Ellipse Sensor Double Support Pin Guide Ring FIGURE 5 DOUBLE SUPPORT PIN ...

Страница 7: ...Ellipse in a level position See Figure 6 NOTE If recommended mounting is not possible care must be taken to ensure that the gage is vented periodically FLOW METERS DEBITMETERS MEDIDOR DE FLUJO F M APPROVED F M APPROVED PFA XXX X inch 250 SWP X XX S N AXXXXXXX 1000 1500 2000 2500 GPM 3000 3500 4000 VENT VALVES FLOW BY PASS VALVE H L FIGURE 6 RECOMMENDED INSTALLATION ...

Страница 8: ...E RS DEBI TMET ERS MEDI DOR DE FLUJ O FLOW METE RS DEBI TMET ERS MEDI DOR DE FLUJ O F M APPROVED F M APPROVED PRESO FIRE PUMP SYSTEM F M APPROVED PFA XXX X inch 250 SWP X XX S N AXXXXXXX 1000 1500 2000 2500 GPM 3000 3500 4000 7 3 Flow Flow Pipe Diameters From Valve PRESO PFA Valve Throttle Valve Throttle Valve System By pass Valve Supply Discharge Optional to Pump Inlet Air Vent Fire Pump PRESO PR...

Страница 9: ...run from the gage vent valves to a pan or drain VIII GAGE OPERATION 1 Identify Hi and Lo pressure inlets on the gage 2 Ensure by pass valve blue is OPEN WARNING WARNING Gage may be damaged if initially pressurized with the by pass valve closed 3 Connect gage to corresponding Hi and Lo pressure taps of the PFA Ellipse via 3 valve manifold if being used 4 Open Hi and Lo instrument valves on the PFA ...

Страница 10: ...Page 10 10 PTT UM 00311 08 12 ...

Страница 11: ... and shall be void with respect to a Product exposed to conditions other than those detailed in applicable technical literature and Installation and Operation Manuals IOMs or which have been subject to vandalism negligence accident acts of God improper installation operation or repair alteration or other circumstances which are beyond the reasonable control of Badger Meter With respect to products...

Страница 12: ... 800 876 3837 414 355 0400 México Badger Meter de las Americas S A de C V Pedro Luis Ogazón N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 México DF México 52 55 5662 0882 Europe Middle East and Africa Badger Meter Europa GmbH Nurtinger Str 76 72639 Neuffen Germany 49 7025 9208 0 Czech Republic Badger Meter Czech Republic s r o Maříkova 2082 26 621 00 Brno Czech Republic 420 5 41420411 Slov...

Отзывы: