Scope of this manual / Product unpacking and inspection / Produkt identification  Page 2/20 
 

OG_IOG_BA_02_1401  

 

2.  Scope of this manual 

This manual contains installation and operation instructions for the Badger Meter industrial 
line of oval gear meters and registers. 
 
Proper performance and reliability of these meters and registers depends upon installation 
in accordance with these instructions. 
 
 

3.  Product unpacking and inspection 

Upon receipt of the product, perform the following unpacking and inspection procedures: 

 
Note:

 If there is damage to the shipping container, request the carrier to be present when 

unpacking the product. 
 
Carefully open the shipping package and follow any instructions marked on the exterior. 
Remove all packing material and carefully lift the product from the package. 
 
Retain the package and all packing material for possible use in reshipment or storage. 
 
Visually inspect the product and applicable accessories for any physical damage such as 
scratches, loose or broken parts, or any other sign of damage that may have occurred 
during shipment. 

 
Note:

 If you find damage, request an inspection by the carrier’s agent within 48 hours of 

delivery and file a claim with the carrier.  
 
A claim for equipment damage in transit is the sole responsibility of the purchaser. 
 
 

4. Product identification 

Record the product identification numbers from the nameplate. 
 
Model # ____________________________________ 

Serial Number # ________________________________  

Tag # ___________________________________(if applicable) 

 
Disclaimer 

The user/purchaser is expected to read and understand the information provided in this 
manual, follow any listed safety precautions and instructions and keep this manual for 
future reference. 
 
Misuse, mishandling, and/or inadequate maintenance may impair performance and/or 
compromise safety. 
 
 
 

 

Содержание IOG Series

Страница 1: ...Badger Meter Europa GmbH Industrial oval gear meter series IOG and registers type ILR 700 ILR 710 ILR 720 ILR 730 ILR 740 ILR 741 INSTALLATION AND OPERATION MANUAL January 2014 OG_IOG_BA_02_1401...

Страница 2: ...factor 8 8 3 Changing the meter pulse rate 9 8 4 Changing the register orientation 9 8 5 Changing the display mode 10 8 6 Exiting Programming Mode 10 9 Additional programming Industrial analog and ind...

Страница 3: ...67 and needs to be protected against dripping water water oils etc Setup operation Adjust only those controls that are covered by the operating instructions Improper adjustment of other controls may...

Страница 4: ...ge and all packing material for possible use in reshipment or storage Visually inspect the product and applicable accessories for any physical damage such as scratches loose or broken parts or any oth...

Страница 5: ...s before operating the equipment Use the equipment only for its intended purpose Do NOT modify or alter the equipment Do NOT leave equipment unattended while dispensing Check equipment daily Repair or...

Страница 6: ...line and meter with fluid before restarting pumps Doing so reduces the possibility of meter damage caused by errant air pressures in the line and meter Make sure all pipe conforms to the same pressur...

Страница 7: ...er operation and program settings for the industrial oval gear series registers Industrial Standard ILR 700 Industrial Pulse ILR 710 Industrial Quadrature Dual Pulse ILR 720 and Industrial Analog ILR...

Страница 8: ...splay the resettable totalizer with five digits or the five least significant digits of the non resettable totalizer RESET and TOTAL is indicated when the resettable total is displayed in the five dig...

Страница 9: ...e of 25 C 77 F and a throughput of 60 000 liters 15 850 gallons 63 400 quarts 126 800 pints US Note A 2 3AA 3 6 VDC battery may also be used as a replacement Figure 4 Low battery indicator 7 6 Checksu...

Страница 10: ...ale factor programming 8 2 Scale factor for models ILR 700 710 720 and 730 The register collects input pulses from the oval gear meter and then determines the appropriate display output using the scal...

Страница 11: ...selected unit of measure is gallons quarts or pints Figure 6 Meter Pulse Rate 1 Press the TOTAL button to select a digit selected digits flash Press RESET to change the selected digit The pulse rate c...

Страница 12: ...he flow rate screen The totalizer screen is depicted below Figure 8 Default display 1 While a letter is flashing on the display press the RESET button to select either totalizer or flow rate 2 Upon co...

Страница 13: ...t Pulse Length should be set to less than the value of t Per the equation Maximum meter flow rate in GPM or l m t x 1000 60X output pulse rate where t the required pulse rate in milliseconds The outpu...

Страница 14: ...to advance to the next screen To advance to the next programming screen hold the TOTAL button for one second 9 3 Analog maximum flow rate for models ILR 730 only Indicated by a H on the left hand side...

Страница 15: ...C Yellow External ground Brown Pulse output White DC Input 6 to 24 VDC 10 to 20mA Outputs Pulse output with internal pull up resistor optional open collector output with output jumper removal pulse ou...

Страница 16: ...nput 6 to 24 VDC 10 to 20mA Outputs Dual pulse output with internal pull up resistor optional open collector output with output jumper removed dual pulse output forms a quadrature signal for direction...

Страница 17: ...White DC input 6 to 24 VDC 10 to 20mA Outputs Analog 4 to 20mA output in loop powered configuration external load of 50 ohms to 250 ohms flow rate is linear scaled between 4mA minimum and 20mA maximu...

Страница 18: ...to the flow Transmitter wiring Reed switch outputs Green and white Ratings Max power 10W not to exceed max voltage 200 VDC peak AC max current 0 5A DC peak AC Outputs Raw reed switch output with no s...

Страница 19: ...r switch must be set to correspond to the size of the meter to properly detect fluid flow Position 1 top 1 2 3 4 1 Position 2 center 1 1 2 Position 3 bottom 2 3 Transmitter wiring Meter size selector...

Страница 20: ...24V DC Supply current 3 5 mA Pulse Output Output current 30 mA max Wiring Yellow Hall effect DC Brown Hall effect ground Green Hall pulse output Reed switch Rating Power rating 10W Switching voltage 1...

Страница 21: ...3 ILR 700 industrial register w screws 66885 001 66885 001 66885 001 66885 001 66885 001 66885 001 66885 001 4 ILR 710 industrial register single pulse output w screws 66885 002 66885 002 66885 002 6...

Страница 22: ...out possible medium wastes remaining in the part For this purpose please use this form A security specification sheet of the medium must accompany this declaration in the following cases Toxical dange...

Страница 23: ......

Страница 24: ...line Phone 49 7025 9208 0 or 79 Fax 49 7025 9208 15 Badger Meter Europa GmbH Subsidiary of Badger Meter Inc USA N rtinger Strasse 76 72639 Neuffen Germany E mail badger badgermeter de www badgermeter...

Отзывы: