Power Source Configurations
POWER SOURCE CONFIGURATIONS
Access to Power
•
The gateway receiver requires access to power . The gateway can use a 120V AC grounded outlet for use with the
AC-to-DC power supply and power cord (PN: 66528-003), or a DC power source for use with the DC power source
cable with 308 in-line connector (PN: 66233-020) .
For a gateway with a LAN PoE configuration, a Power over Ethernet
connection is required . Diagrams of each power source configuration start on
page 18
.
•
Outlet and enclosure (if required) should be mounted for easy accessibility by authorized utility personnel at the
installation site .
•
Consult the appropriate electrical, building and industry codes, regulations and standards for accepted installation
practices for use of the AC-to-DC power supply and outlet in environmentally controlled indoor locations .
Use of a NEMA 4 Enclosure
AC-to-DC power supply used outdoors or in a non-environmentally controlled indoor location requires a customer-supplied
NEMA 4 enclosure, or equivalent, installed in accordance with appropriate electrical codes, building codes, industry codes,
regulations and standards .
Recommended Installation Configurations
These are the standard recommended installation configurations with various combinations of backhaul and power source:
•
CDMA with 120V AC power source
•
LAN with 120V AC power source
•
CDMA with DC power source
•
LAN with DC power source
•
LAN with PoE power source
Diagrams of the above configurations are shown on the pages that follow . Consult the appropriate diagram for your
installation configuration .