Badger Meter Flo-tech Flo-Check F7164 Series Скачать руководство пользователя страница 27

Flow vs Pressure Drop Charts, ∆P Captured Using Loading Valves

Series

Dimensions (L x D x H)

Weight

lbs (kg)

in.

mm

F7164

11 41 × 5 70 × 7 93

289 81 × 144 78 × 201 42

17 (7 71)

F7160

11 41 × 5 70 × 7 93

289 81 × 144 78 × 201 42

17 (7 71)

F7161

12 10 × 6 20 × 7 93

307 34 × 157 48 × 201 42

20 (9 07)

F7165

11 41 × 5 70 × 7 93

289 81 × 144 78 × 201 42

17 (7 71)

F7162

11 41 × 5 70 × 7 93

289 81 × 144 78 × 201 42

17 (7 71)

F7163

12 10 × 6 20 × 7 93

307 34 × 157 48 × 201 42

20 (9 07)

FLOW VS PRESSURE DROP CHARTS, ∆P CAPTURED USING  

LOADING VALVES

60

50

40

30

20

10

0

0       10      20      30       40      50      60      70      80      90     100 

F7160, F7162

PRESSURE DROP

 PSI

FLOW GPM

0     20     40     60     80    100   120   140   160   180   200   220 

FORWARD
REVERSE

FORWARD
REVERSE

40

35

30

25

20

15

10

5

0

F7161, F7163

PRESSURE DROP

 PSI

FLOW GPM

Figure 14:  Flow vs pressure drop

OTE: 

N

For Flow vs Pressure Drop information on the F7164 and F7165 models, please contact the factory 

RETURN GOODS AUTHORIZATION

When returning equipment for service, a Returned Goods Authorization (RGA) number must be obtained from our Customer 

Service Department  Please contact them by phone at 877-243-1010 
All returns go to the following address and must include the RGA number on the outside of the box:
Badger Meter, Inc 
8635 Washington Avenue
Racine, WI 53406-3738 USA
Attn: RGA # xxx-xxxx

WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) DIRECTIVE

In the European Union, this label indicates that this product should not be disposed of with household 

waste  It should be deposited at an appropriate facility to enable recovery and recycling 
For information on how to recycle this product responsibly in your country, please visit  

www badgermeter com 

Page 27 

June 2022

TST-UM-02433-EN-02

Содержание Flo-tech Flo-Check F7164 Series

Страница 1: ...Portable Hydraulic Testers USB Hydraulic System Analyzer TST UM 02433 EN 02 June 2022 User Manual...

Страница 2: ...Portable Hydraulic Testers USB Hydraulic System Analyzer Page ii June 2022 TST UM 02433 EN 02...

Страница 3: ...w 9 Running the Software and Viewing Realtime Data 10 Recording Measurements to a File 10 Recording a File 11 Recording a File While in Run Mode 11 Entering Run or Record Mode 12 Recording Modes 12 Lo...

Страница 4: ...res 18 Standard Test Conditions 18 Tee Test 19 Inline System Test 20 Control Valve and Bi directional Hydraulic Motor Test 21 Bi directional Cylinder Test 22 Hydrostatic Transmission Diagnostics 23 Ot...

Страница 5: ...nsibility of the purchaser OVERVIEW The Flo Check USB Hydraulic System Analyzer can be used as a stationary or portable tester for both industrial and mobile hydraulic system diagnostics and analysis...

Страница 6: ...ty factor capable of 10 000 PSI 689 Bar transients Operating Pressure 6000 PSI 414 Bar 41 4 MPa 420 kg cm capable of 10 000 PSI 689 Bar transients Internal Burst Disc 7500 PSI DP Pressure Drop See Flo...

Страница 7: ...n kg cm 611 H P liters min kg cm 456 2 H P liters min MPa 44 74 kW liters min Bar 600 kW liters min MPa 60 Make all tests at the same operating temperature to provide consistency of results A typical...

Страница 8: ...lic System Analyzer interface uses the Microsoft Human Interface Driver HID This driver is installed with Windows operating systems that support USB The first time you connect the device to your PC yo...

Страница 9: ...as a menu bar buttons with common functions and alarm indicators Figure 1 Flo Check USB hydraulic system analyzer screen Measurement over a 1 second time period Color Indication Alarm Indication Digit...

Страница 10: ...l measurements can be saved to a comma separated value csv file This file type is a generic text file with the data separated by commas and can be read by many spreadsheet applications such as Excel a...

Страница 11: ...uble click on the file from the list Data on the digital displays and the strip chart is updated once per second The message Recording also displays under the Run button to indicate the software is in...

Страница 12: ...ptured Point displays under the Run button for approximately one second to indicate the software has recorded one point to the csv file 5 Continue clicking Manual Capture to append more points to the...

Страница 13: ...roll through the data The current incoming data is not lost while you view the history data so you can view it while the Hydraulic System Analyzer is in Run or Record mode When finished viewing the hi...

Страница 14: ...all alarm events time value alarm level in another form These alarm events are also recorded to the csv file when in Record mode Changing Alarm Settings 1 If in the Run or Record mode click Stop 2 Se...

Страница 15: ...nu to display the alarm events for each measurement Figure 5 Alarm History screen 3 Click Clear History at the bottom of the form to erase captured alarms 4 Click the red X in the upper right corner t...

Страница 16: ...XP and Windows 2000 is C Documents and Settings user name My Documents Flo tech Hydraulic System Analyzer Configurations The default location for saving a configuration file for Windows Vista is C Use...

Страница 17: ...without worrying about calibration files Resetting Zero for the Pressure Transducer 1 Select Tools Calibration from the main menu Figure 6 Calibration screen 2 Select the Pressure or Flow radio butto...

Страница 18: ...DRAULIC COMPONENTS SPECIFIC SYSTEMS MAY REQUIRE SPECIFIC TEST PROCEDURES Standard Test Conditions 1 Install the Hydraulic System Analyzer as described in one of the following test procedures Tee Test...

Страница 19: ...livers a constant low flow at zero pressure and at maximum pressure suggests suction problems Relief Valve Test 1 Put a control valve into a power output mode with the output flow blocked such as a cy...

Страница 20: ...ecifications A decrease in flow from zero pressure to maximum pressure indicates the pump condition A pump that delivers a constant low flow at zero pressure and at maximum pressure suggests suction p...

Страница 21: ...ency Control Valve and Bi directional Hydraulic Motor Test Flo Check Figure 9 Control Valve and Bi directional Hydraulic Motor Test Motor Test No Load 1 Open the Hydraulic System Analyzer loading valv...

Страница 22: ...e flow and RPM meet specifications it could indicate a relief valve problem or DCV problem For complete information visit www badgermeter com and select Petroleum Fluids under Products Variable Area H...

Страница 23: ...iagnostics Install the Hydraulic System Analyzer into the system between the pump discharge port and the inlet of the hydraulic motor PV Flow Bi directional Reservoir Case Drain MF Flo Check Figure 11...

Страница 24: ...load indicates a loss of the motor s efficiency OTE N If the motor does not have a case drain it cannot be loaded on the discharge side Other Test Procedures Case Drain You can check the case drain f...

Страница 25: ...flow reading may indicate a blockage of the turbine 1 Remove the retaining ring from the inlet port and carefully remove the turbine assembly Remove any material that may be preventing easy rotation o...

Страница 26: ...hen the second burst disc 5 Verify that the burst discs are seated Be careful not to scratch the surface of the discs 6 Insert the burst disc housing with the O ring and backup O ring into the port of...

Страница 27: ...ure 14 Flow vs pressure drop OTE N For Flow vs Pressure Drop information on the F7164 and F7165 models please contact the factory RETURN GOODS AUTHORIZATION When returning equipment for service a Retu...

Страница 28: ...ring in this document are the property of their respective entities Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product or system specifi...

Отзывы: