ABOUT THIS MANUAL
This manual contains information concerning the installation, operation and maintenance of the Badger Meter® ER-9 Digital
Resettable Totalizer and Rate of Flow Indicator (ER-9) . To ensure proper performance, the instructions given in this manual
should be thoroughly understood . Keep this manual for future reference .
Installation, wiring and programming of the unit is fairly simple and straightforward . This manual is designed to provide you
with a step-by-step guide for this purpose .
Examples are provided only to facilitate programming . Your specific application will most likely require a different set of
numbers for proper programming .
The troubleshooting section lists the most common problems that can be encountered, their most likely cause and the
recommended solution . See
.
PRODUCT DESCRIPTION
The ER-9 is an external or battery powered indicator that displays rate of flow and total flow . The ER-9 also has a scalable pulse
output . It has independent programmable scale factors for rate and totalization, allowing you to program these displayed
values in different but meaningful engineering units, such as gallons per minute and total gallons .
The supertwist LCD display with 8 digits for total, and 4 digits plus legend for rate, provides easy viewing at a glance . For
conditions where ambient light is poor, the display can be backlit by connecting an external DC (10…28V DC) power supply .
A single unit can accept NPN or dry contact inputs for low or high speed applications .
The ER-9 is powered by two replaceable 3V lithium batteries . You can install a new battery before removing the old one,
thereby retaining count total and program data . A low battery indicator appears on the screen about two weeks before the
end of the battery life . See
“Battery Installation/Replacement” on page 6
.
The unit operates in battery mode for at least six
months . To extend battery life to five years, connect the unit to an external DC power source .
Setup is quick and easy as the two front panel keys are used to scroll through and preset values in all program mode choices .
User Manual
Page 5
August 2018
REG-UM-00836-EN-12