Badger Meter ER-9 Скачать руководство пользователя страница 14

Replacing the Meter's Sensor Pickup

OP

TURBO

DISC

IND’L

Figure 6:  Meter mount components

To replace the sensor pickup on your meter, follow these steps:

Industrial turbo meter

1 .  Remove the front cover from the ER-9 unit and disconnect all wiring .
2 .  Remove meter head bolts and the lift meter head assembly from the housing .
3 .  Remove the retaining ring that holds the accessory unit to the head .
4 .  Loosen the side seal screw on the accessory adapter, twist 90° and pull entire assembly unit from the meter head .
5 .  Twist the drop pipe in counterclockwise direction to remove it and the ER-9 unit from the adapter assembly .
6 .  Attach the new adapter assembly to the drop pipe and ER-9 unit .
7 .  Reverse the balance of the above steps to re-assemble the unit .

Disc meter

1 .  Remove the front cover on the ER-9 unit and disconnect the sensor wiring .
2 .  Loosen the side seal screw on the assembly adapter, twist the adapter 90° and lift the entire accessory unit off the 

bare meter .

3 .  Pull the reed switch pickup assembly and pad from the adapter .
4 .  Replace the reed switch pickup and pad in the adapter, feeding the wires up through the drop pipe .
5 .  Reposition the entire assembly on meter .
6 .  Rewire the sensor to the ER-9 unit .

Oscillating piston meter

1 .  Remove the front cover on the ER-9 unit and disconnect the sensor wiring .
2 .  Remove the back plate on the meter to expose the pickup assembly .
3 .  Remove the reed switch pickup assembly and replace it .
4 .  Feed the wires up through the drop pipe .
5 .  Reassemble the back plate to the meter .
6 .  Rewire the sensor wires to the ER-9 unit .

Industrial Registers, Model ER-9 Digital Resettable Totalizer

Page 14 

August 2018

REG-UM-00836-EN-12

Содержание ER-9

Страница 1: ...M 00836 EN 12 August 2018 User Manual Industrial Registers Model ER 9 Digital Resettable Totalizer and Rate of Flow Indicator Plus Pulse Output ER 9 Indicator ER 9 Register For Portable Large Meter Te...

Страница 2: ...Industrial Registers Model ER 9 Digital Resettable Totalizer Page ii August 2018 REG UM 00836 EN 12...

Страница 3: ...ons 7 Wiring Terminals 7 Transmitter Connections 7 Operation 8 Display Types 8 Control Keys 8 Programming 9 Totalizer Programming 10 Rate of Flow Programming 10 Pulse Output Programming 11 Troubleshoo...

Страница 4: ...Industrial Registers Model ER 9 Digital Resettable Totalizer Page iv August 2018 REG UM 00836 EN 12...

Страница 5: ...tput It has independent programmable scale factors for rate and totalization allowing you to program these displayed values in different but meaningful engineering units such as gallons per minute and...

Страница 6: ...lace batteries before they are completely exhausted to retain programming and indicated volume If two batteries are present remove and replace one battery at a time If only one battery is present inst...

Страница 7: ...inal numbers on the ER 9 Connect the wire coming from the transmitter to the corresponding terminal number for the ER Remote models Connecting to a Generic Reed Switch To connect a generic reed switch...

Страница 8: ...he Flow Total and the Flow Rate The letter R on the left of the screen indicates that the Flow Rate is being displayed Programming mode The Down Arrow key toggles the unit between the Total Display an...

Страница 9: ...he decimal point on the totalizer display from no decimal OFF to 0 00000 R 3 1 000 Mode 3 Rate Scale Factor Decimal Point sets the decimal in Rate Scale Factor number from no decimal to 0 000 R 4 9999...

Страница 10: ...asure for any time base such as gallons minute liters second barrels hour Rate scale factor To determine the Rate Scale Factor Program Mode 4 use the following formula Rate Scale Factor Seconds Transm...

Страница 11: ...L 198 340 52 396 1484 689 3 4 35 RCDL 126 671 33 463 947 566 1 40 RCDL 89 781 23 717 671 610 1 55 RCDL 58 064 15 339 434 351 1 70 RCDL 46 752 12 350 349 726 1 1 2 120 RCDL 23 867 6 305 178 539 2 170 R...

Страница 12: ...ctions 3 Repair or replace transmitter Cannot program Program enable jumper is not installed or is installed improperly Install jumper Cannot reset from front panel Reset enable is not programmed Repr...

Страница 13: ...calibrated vessel 5 Determine the number of pulses per gallon by dividing the indicator reading by the number of gallons of fluid in the vessel Use this value for your calculations Example You progra...

Страница 14: ...assemble the unit Disc meter 1 Remove the front cover on the ER 9 unit and disconnect the sensor wiring 2 Loosen the side seal screw on the assembly adapter twist the adapter 90 and lift the entire ac...

Страница 15: ...Power Source Type Dual 3V Lithium battery Replacement part 62576 001 Battery life expectancy 5 years typical if using external DC supply 6 months if used alone with 50 duty cycle output Low power ind...

Страница 16: ...Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus Badger Meter Europe ul Korfantego 6 44 193 Knur w Poland 48 32 236 8787 Europe Middle East and Africa Badger Meter Europa GmbH...

Отзывы: