Page 9 

September 2015

AUT-UM-01734-EN-03

Meter Installation 

Attach Meter to Hose

1   Close the drain valve 

2   Attach a swivel to the meter  
3   Apply thread sealant Loctite® 243 , or equivalent, to the male end of hose  

4   Insert the metal end of the hose into the swivel  
5   Tighten completely with an open ended, adjustable, wrench 

OTEE:

N

The threaded end of the meter always has female threads  The metal end of the 

hose must have male threads 

6   Apply thread sealant, Loctite® 243, or equivalent, to the male end   

The inlet and outlet swivel connections are either 1/2" NPT or 1/2" BSPP, depending on 

meter model 

Attach Nozzle to Meter

1   On the opposite end, apply sealant Loctite® 243, or equivalent, to the end of the nozzle  

2   Thread the nozzle onto the meter  Screw it in tightly with an open ended, 

adjustable wrench 

3   Open all dispense position shut-off valves  
4   Start the pump to pressurize the system 
5   Before use, purge all air from the fluid lines and dispense valve(s) 

Содержание epm-3

Страница 1: ...Electronic Preset Meter Model EPM 3 RF 2 4 GHz AUT UM 01734 EN 03 September 2015 User Manual...

Страница 2: ...Electronic Preset Meter Model EPM 3 RF 2 4 GHz Page ii September 2015...

Страница 3: ...ure 8 Grounding 8 Flushing Procedure 8 Attach Meter to Hose 9 Attach Nozzle to Meter 9 Meter Operation RF Mode 10 Connecting to an FMS Network 10 History Icon 11 Error Codes 11 Meter Operation EPM Mod...

Страница 4: ...Changing the Unit of Measure 16 Changing the Scale Factor 17 Verifying Changes 17 Enabling or Disabling the EPM Mode 17 Network Program 18 Power Level Display 18 Saving Changes 18 Dimensions 19 Speci...

Страница 5: ...essional use only Read all instructions tags and labels before operating the equipment Use the equipment only for its intended purpose Do not modify or alter the equipment Do not leave equipment unatt...

Страница 6: ...ct Identification Information Record the product identification numbers from the nameplate here Model Number _______ Serial Number _______ Tag Number _______ if applicable Certification Contains FCC I...

Страница 7: ...n reached A top off feature allows additional fluid to be dispensed and tracked after the batch quantity has been dispensed Upon completion of the dispense press RESET The meter locks prohibiting any...

Страница 8: ...w manufacturer s recommendations Air and fluid hoses use only grounded hoses Air compressor follow manufacturers recommendations Fluid supply container follow the local code MOVEMENT OF FLUIDS THROUGH...

Страница 9: ...hreads The metal end of the hose must have male threads 6 Apply thread sealant Loctite 243 or equivalent to the male end The inlet and outlet swivel connections are either 1 2 NPT or 1 2 BSPP dependin...

Страница 10: ...id valve automatically locks the dispensing valve in the full open position The trigger falls back to the closed position After the batch quantity is dispensed the flow automatically shuts off DO NOT...

Страница 11: ...rking To clear the error press RESET F02 The meter is not configured to a keypad To clear the error code press RESET Verify that the meter radio address is configured properly F03 System busy To clear...

Страница 12: ...Batch Mode the batch quantity displays in the lower right corner of the screen 1 Change the batch size by pressing the 10 1 and or 0 1 a Press 10 to increase the batch amount in increments of 10 units...

Страница 13: ...s two flow totalizers Resettable Total and Accumulated Total 1 Press and hold TOTAL to see the Accumulated Total 2 Continue holding TOTAL for three seconds to see the Resettable Total RESETTOTAL displ...

Страница 14: ...at the factory It may have been revised after field installation Use the Scale Factor showing on the display not the one written on the trigger IMPORTAN I Changing the Scale Factor changes the accura...

Страница 15: ...art of Approximate Scale Factors for Fluids of Different Viscosities Fluid Viscosity Scale Factor Water Anti Freeze 5 1 044 Anti Freeze 18 1 007 Brake Fluid 42 1 004 ATF 80 1 002 10W 140 1 000 80W 90...

Страница 16: ...o decrement a PIN digit 5 Press RESET to confirm PIN and enter the programming mode with Scale Factor and Unit of Measure screen displayed 6 Press and hold AUTO and TOTAL for 2 seconds to exit Program...

Страница 17: ...ts in Scale Factor 5 If no Scale Factor changes are necessary press and hold TOTAL and AUTO until the display flashes three times then goes blank OR Press RESET to advance to the EPM Manual Mode Enabl...

Страница 18: ...evel Display screen NOTE N You can view the radio network by pressing and holding TOTAL and 10 simultaneously when not in Programming Mode Power Level Display 1 The radio power level is set at the fac...

Страница 19: ...pm Operating Pressure Range 5 1000 psi 0 35 67 bar Operating Temperature Range 20 120 F 5 50 C Accuracy Oils 0 5 0 5 Accuracy Anti freeze 1 5 1 5 5 Digit LCD Display 10 mm high x 5 mm wide displays Qu...

Страница 20: ...Page 20 September 2015 AUT UM 01734 EN 03 Parts List PARTS LIST Item Description Part Number 1 Battery holder assembly 64103 026 2 Bottom case with screws and radio 64103 029 3 Solenoid 64786 002...

Страница 21: ...21 September 2015 AUT UM 01734 EN 03 Parts List 1 2 3 Item Description Part Number 1 Rubber boot 65546 001 2 Display assembly 64103 023 3 RF register assembly 64103 030 Not Shown Swivel NPT AFLAS 6408...

Страница 22: ...Page 22 September 2015 AUT UM 01734 EN 03 Parts List 1 2 3 Item Description Part Number 1 Valve assembly AFLAS 64103 020 2 LCP gear set with AFLAS o ring 62896 003 3 Trigger assembly 64103 015...

Страница 23: ...ry connection Press RESET Batteries dead Replace batteries Press RESET Meter does not latch for batching Meter not in AUTO mode Press AUTO and program the batch size Meter not reset after prior batch...

Страница 24: ...to continuous research product improvements and enhancements Badger Meter reserves the right to change product or system specifications without notice except to the extent an outstanding contractual o...

Отзывы: