SPECIFICATIONS
E-Series G2 Ultrasonic
Meter Size
3 in.
4 in.
6 in.
8 in.
3 × 12 in
(76 × 305 mm)
3 × 17 in
(76 × 432 mm)
4 × 14 in
(102 × 356 mm)
4 × 20 in
(102 × 508 mm)
6 × 18 in
(152 × 457 mm)
6 × 24 in
(152 × 610 mm)
8 × 20 in
(203 × 508 mm)
Normal Test Flow Limits
0 75…560 gpm
1 5…1100 gpm
2 2…2000 gpm
4…3500 gpm
Minimum Test Flow Limits
0 37 gpm
0 75 gpm
1 1 gpm
2 0 gpm
Safe Maximum Operating
Condition (SMOC)
560 gpm
1100 gpm
2000 gpm
3500 gpm
Typical Pressure Loss
2 6 psi @ 350 gpm
2 1 psi @ 630 gpm
1 5 psi @ 1400
gpm
1 8 psi @ 1400
gpm
2 4 psi @ 2800
gpm
Totalization Display
Resolution
3 in. and 4 in. meters
• Gallons: 0 1
• Cubic feet: 0 01
• Cubic meters: 0 001
6 in. and 8 in. meters
• Gallons: 1 0
• Cubic feet: 0 1
• Cubic meters: 0 01
Operating Performance
In normal temperature range of 45…122 °F (7…50 °C), new meter consumption measurement is accurate to:
• 100% ±1 5% over the normal test flow limits
• 100% ±3 0% for the minimum test flow limits
Storage Temperature
– 40…140° F (– 40…60° C)
Maximum Ambient
Storage
(Storage for One Hour)
150° F (66° C)
Measured Fluid
Temperature Range
34…140° F (1…60° C)
Humidity
0…100% condensing; meter is capable of operating in fully submerged environments
Maximum Working
Pressure of Meter Housing
175 psi (12 bar)
Maximum Operating
Pressure of Pressure
Sensor
150 psi (10 bar)
Pressure Sensor Accuracy
±
2% of full scale pressure, up to 150 psi (10 bar)
Register Type
Straight reading, permanently sealed electronic LCD; digits are 0 28 in (7 mm) high
Register Display
• Consumption (up to nine digits)
• Rate of flow
• Alarms
• Pressure
• Temperature
• Firmware version
• Unit of measure factory programmed for gallons,
cubic feet and cubic meters
Scaled/Unscaled Output*
Solid-state relay with 4-20mA output; open drain MOSFET with encoder output
Max Voltage 30V DC
Current 100 mA
Pulse Width 50 ms (programmable 30…100 ms)
Analog 4-20 mA Output*
Two-wire/passive
Input Voltage Range 9…50V DC supply
Current 4…20 mA
Max Load Resistance
(Ohms) 50 Ohms + 50 Ohms (supply voltage - 9V)
Battery
3 6-volt lithium thionyl chloride; battery is fully encapsulated within the register housing and is not replaceable; 10-
year battery life
*
Applicable to meters with dual output options
E-Series G2® Ultrasonic Meters, Lead-Free Bronze Alloy, 3, 4, 6, 8 inch
www.badgermeter.com
BEACON, E-Series, E-Series G2 and ORION are registered trademarks of Badger Meter, Inc Other trademarks appearing in this document are the property of their respective entities
Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the
extent an outstanding contractual obligation exists © 2021 Badger Meter, Inc All rights reserved