ESM-UM-02782-EN-12
METER ALARMS
E-Series Ultrasonic meter alarms appear on the display as icons that illuminate when the condition occurs Alarms are
displayed for the number of days listed in the table below Alarms also appear as 3-character codes on the alarm and
operating mode screen See
"Alarm and Operating Mode Screen" on page 10
Alarms are sent as part of the encoder message to AMR/AMI systems that are capable of receiving an extended message, such
as ORION Cellular, Fixed Network (SE) and Migratable (ME) endpoints The details can also be read through an IR interface
OTE:
N
Meters are delivered in storage mode so that an alarm is not triggered In storage mode, the meter LCD displays an
empty pipe icon, but no error code is sent to the endpoint For alarms reported within BEACON, refer to BEACON
Help at
Alarms
Icon
Alarm Description
Number of Days
Icon Displays
High Resolution with ORION
Cellular, Fixed Network (SE)
or Migratable (ME)
Normal Meter
Operation
Meter operating correctly
n/a
n/a
Temperature
Temperature outside limits: above 140° F or below 34° F
Meter continues to operate but is outside specified range
Alarm clears after 35 days
unless condition continues
Meter sends consumption and
alarm to the endpoint once
per occurrence
Pressure*
Pressure sensor is damaged, or pressure is outside
specified threshold limits: above
130 psi
or below 20 psi
If maximum operating pressure is exceeded,
P
999 PSI
(or
P 99.9 bAr
)
displays until pressure is back within the
specified range If the pressure sensor is damaged,
P Err
PSI
(or
P Err bAr
) will display
Alarm clears after 35 days
unless condition continues
Empty Pipe
Empty or partially filled pipe Last known good read
is displayed
If the meter is active and detects an empty pipe, water
temperature displays
ErrF
(or
ErrC
) If meter is in storage
mode and detects an empty pipe, water temperature
displays
– – – F
(or
– – – C
)
Alarm clears when pipe
is filled
Measurement
Error
Interference of ultrasonic signal Meter is not measuring
properly Meter continues to operate unless sensors
are damaged
Alarm clears after 35 days
unless condition continues
Exceeding
Max Flow
Maximum flow rate exceeded No consumption is
accumulated until flow is back within
specified range
Alarm clears after 35 days
unless condition continues
Meter sends consumption and
alarm to the endpoint once per
occurrence
Reverse Flow
Meter detects 10 gal of reverse water flow, triggers the
reverse flow alarm icon on the display and sends alarm
message to the endpoint
Alarm clears after 35 days
unless condition continues
Meter detects reverse flow and
sends alarm to the endpoint
once per occurrence
No Usage
Flow rate less than the low flow operating rate for
30 days
Alarm clears automatically
once flow occurs
Meter detects no usage and
sends alarm to the endpoint
once per occurrence
Suspected Leak
Flow rate more than the low flow operating rate for 24
hours
Alarm clears automatically
when flow rate drops below
low flow operating rate
Meter detects suspected leak
and sends alarm to the endpoint
once per occurrence
End of Life
Battery nearing end of life
Alarm is activated
after 9 5 years and does
not clear
Meter sends alarm message
to the endpoint once per
occurrence
Program Alert
n/a
Meter has been programmed in last 35 days
n/a
Meter sends alarm message
to the endpoint once per
occurrence
*When used in conjunction with ORION Cellular LTE-M or LTE endpoints, pressure data and alarms are sent as part of the encoder message and surfaced in
BEACON SaaS
Meter Alarms
Page 14
December 2021