E-Series G2® Ultrasonic Meters

Lead-Free Bronze Alloy, 3, 4, 6, 8 inch

ESM-UM-02782-EN-12 (December 2021) 

User Manual

Содержание E-Series G2

Страница 1: ...E Series G2 Ultrasonic Meters Lead Free Bronze Alloy 3 4 6 8 inch ESM UM 02782 EN 12 December 2021 User Manual...

Страница 2: ...acking and Inspection 5 Rigging Lifting and Moving Large Units 5 Installation 6 Pre Installation 6 Installation Instructions 7 Accuracy Test 8 Operations 8 Display 8 Activating the Display 8 Display S...

Страница 3: ...es Ultrasonic meter features lead free bronze alloy meter housing ultrasonic transducers a meter control circuit board with associated wiring LCD and battery Wetted elements are limited to the pressur...

Страница 4: ...tion Figure 2 Water Pressure and Temperature sensors selection 3 Select the Water Pressure and Water Temperature check boxes to turn on reporting for the meter sensors 4 Select Update Utility at the b...

Страница 5: ...ow these unpacking and inspection procedures If damage to a shipping container is evident upon receipt of a meter request that a representative of the carrier be present when the meter is unpacked Car...

Страница 6: ...pipe is recommended upstream of the meter Do not install check valves or pressure reducing devices within 5 pipe diameters upstream of the meter Only fully open gate or ball valves should be used imm...

Страница 7: ...bolts 9 Check the existing position for proper alignment and spacing Correct any misalignment or spacing issues 10 Install the meter in the pipeline in a horizontal or vertical position with the flow...

Страница 8: ...digit Liquid Crystal Display LCD that toggles to show consumption rate of flow temperature pressure alarm and operating mode and firmware version When configured for dual outputs the scaled output and...

Страница 9: ...ith a resolution of 0 1 gallons 10 million cubic feet with a resolution of 0 01 cubic feet or one million cubic meters with a resolution of 0 001 cubic meter 6 8 inch meters Totalized flow displays up...

Страница 10: ...nsition mode when there is a full pipe When used in conjunction with ORION Cellular LTE M or LTE endpoints temperature data is sent as part of the encoder message and surfaced in BEACON SaaS Water Tem...

Страница 11: ...each unit of measure in Figure 16 The unscaled pulse output does not have a dedicated display screen Default values are shown in the chart in Figure 16 Figure 15 Scaled pulse output Meter Size Pulse...

Страница 12: ...and installation to AMR AMI endpoints It is also available with a flying lead for field splice connection The in line connector is recommended for pit applications Dual Output The E Series Ultrasonic...

Страница 13: ...CK Ground RED Power GREEN Data BLACK Ground Encoder cable with flying lead Scaled unscaled cable with flying lead Figure 18 Encoder and scaled unscaled output wiring options Encoder and 4 20 mA 4 20 m...

Страница 14: ...y filled pipe Last known good read is displayed If the meter is active and detects an empty pipe water temperature displays ErrF or ErrC If meter is in storage mode and detects an empty pipe water tem...

Страница 15: ...asurement error 004 End of life 013 Empty pipe Temperature Reverse flow 100 Pressure 008 No usage 018 No usage Reverse flow 101 Empty pipe Pressure 009 Empty pipe No usage 020 Suspected leak 140 Progr...

Страница 16: ...10 bar Pressure Sensor Accuracy 2 of full scale pressure up to 150 psi 10 bar Register Type Straight reading permanently sealed electronic LCD digits are 0 28 in 7 mm high Register Display Consumptio...