Turbine replacement
TURBINE REPLACEMENT
The Model 1100 turbine flow meter uses wear-resistant moving parts to provide trouble-free operation and long service life .
Designed for easy field service of a damaged flow meter, Model 1100 repair kits replace only the internal parts, not the entire
flow meter . Repair parts use stainless steel alloys and tungsten carbide construction materials .
Each repair kit is factory calibrated to provide accuracy throughout the entire flow range . Each kit is complete and includes
a new K-factor, which is the calibrated number of pulses generated by each gallon of liquid . Recalibration of the monitor or
other electronics uses the K-factor to provide accurate output data .
OTE:
N
If the meter repair kit part number ends in
NCC
(no calibration), it was not factory calibrated . For these repair kits, use
the nominal K-factor .
Turbine Replacement Kit Part Number
Flow Meter Size
Replacement Kit Fits
Meter Part Number
Repair Kit Part Number
3/8 in .
B110-375, B110-375-1/2
B251-102
1/2 in .
B110-500, B110-500-1/2
B251-105
3/4 in .
B110-750, B110-750-1/2
B251-108
7/8 in .
B110-875
B251-109
1 in .
B111-110
B251-112
1-1/2 in .
B111-115
B251-116
2 in . Low
B111-121
B251-116
2 in .
B111-120
B251-120
3 in .
B111-130
B251-131
4 in .
B111-140
B251-141
6 in .
B111-160
B251-161
8 in .
B111-180
B251-181
10 in .
B111-200
B251-200
Standard Magnetic Pick-up
All Meter Sizes
B111109
Table 2: Repair kit part numbers
Turbine Assembly Removal
HIGH-PRESSURE LEAKS ARE DANGEROUS AND MAY CAUSE PERSONAL INJURY. MAKE SURE TO SHUT OFF FLUID FLOW
AND RELEASE RESIDUAL PRESSURE IN THE LINE BEFORE ATTEMPTING TO REMOVE THE METER.