Installation

All Badger Meter Model 1100 turbine meters use stainless steel and tungsten carbide construction materials . Make sure the 

operating fluid is compatible with these materials . Incompatible fluids can cause deterioration of internal components and 

cause a reduction in meter accuracy .
The measured liquid should be free of any large particles that may inhibit rotation of the turbine blades . If particles are 

present, install a mesh strainer upstream before operating the flow meter . See 

Table 1 

for strainer recommendations .

Part Number

Strainer Mesh

Clearance

Filter Size

B110-375

60

0 .0092 in .

260 μm

B110-500

60

0 .0092 in .

260 μm

B110-750

60

0 .0092 in .

260 μm

B110-875

60

0 .0092 in .

260 μm

B111-110

60

0 .0092 in .

260 μm

B111-115

20

0 .0340 in .

0 .86 mm

B111-120

10

0 .0650 in .

1 .6 mm

B111-121

20

0 .0340 in .

0 .86 mm

B111-130, B117-130

8

0 .0900 in .

2 .3 mm

B111-140, B117-140

10

0 .0650 in .

1 .6 mm

B111-160

4

0 .1875 in .

4 .8 mm

B111-180

8

0 .0900 in .

2 .3 mm

B111-200

4

0 .1875 in .

4 .8 mm

Table 1: Strainer mesh installation details

The preferred plumbing setup is one containing a bypass line (see 

Figure 3 on page 6

) that allows meter inspection and 

repair without interrupting flow . If a bypass line is not used, it is important that all control valves be located downstream of 

the flow meter (see 

Figure 4 on page 6

) .

STRIKING AN EMPTY METER WITH HIGH VELOCITY FLOW STREAM CAN CAUSE DAMAGE.

ATTENTION

DES DOMMAGES PEUVENT ÊTRE PROVOQUÉS EN FRAPPANT UN MÈTRE VIDE AVEC UN JET D’ÉCOULEMENT DE VITESSE 

ÉLEVÉE.

Any restriction in the flow line may cause the liquid to flash . If necessary, install air eliminators so that the meter is not 

incorrectly measuring entrained air or gas .
Badger Meter recommends installation of a minimum straight pipe length, equal to ten (10) pipe diameters on the upstream 

side and five (5) diameters on the downstream side of the flow meter . Otherwise, meter accuracy may be affected . Piping 

should be the same size as the meter bore or threaded port size .
Severe pulsation and mechanical vibration affect accuracy and shorten the life of the meter . If this condition is present, 

consider using a flow meter possessing superior resistance to pulsation and vibration like the Badger Meter QuikSert . Do not 

locate the flow meter or connection cable close to electric motors, transformers, sparking devices, high voltage lines, or place 

connecting cable in conduit with wires furnishing power for such devices . These devices can induce false signals in the flow 

meter coil or cable, causing the meter to read inaccurately .
If problems arise with the flow meter, consult the 

Troubleshooting Guide on page 12

 . If further problems arise, consult 

the factory .
Replace damaged internal components of the turbine flow meter with a turbine meter repair kit available from Badger Meter . 

See 

Turbine Replacement on page 8

 .

Page 5 

November 2022

TUR-UM-00014-EN-09

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание Blancett 1100 Series

Страница 1: ...Turbine Flow Meter 1100 Series Turbine Meter TUR UM 00014 EN 09 November 2022 User Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...7 Operational Startup 7 Turbine Replacement 8 Turbine Replacement Kit Part Number 8 Turbine Assembly Removal 8 Disassembly 9 New Turbine Kit Installation 10 Part Number Information 11 Troubleshooting...

Страница 3: ...y profile Fluid then passes through the turbine causing it to rotate at a speed proportional to the fluid velocity As each turbine blade passes through the magnetic field the blade generates an AC vol...

Страница 4: ...s INSTALLATION PRESSURE IN EXCESS OF ALLOWABLE RATING MAY CAUSE THE HOUSING TO BURST AND CAUSE SERIOUS PERSONAL INJURY AVERTISSEMENT LA PRESSION AU DESSUS DE L ESTIMATION PERMISE PEUT FAIRE CLATER ET...

Страница 5: ...AUSE DAMAGE ATTENTION DES DOMMAGES PEUVENT TRE PROVOQU S EN FRAPPANT UN M TRE VIDE AVEC UN JET D COULEMENT DE VITESSE LEV E Any restriction in the flow line may cause the liquid to flash If necessary...

Страница 6: ...eter 10 Pipe Diameters Figure 3 Meter installation with a bypass line 2 1 Electronic Flow Monitor Control Valve 5 Pipe Diameters Turbine Flow Meter 10 Pipe Diameters Figure 4 Meter installation withou...

Страница 7: ...T LIB R E AVANT D ESSAYER D INSTALLER LE M TRE DANS UN SYST ME ACTUEL After meter installation close the isolation valves and open the bypass valve Allow liquid to flow through the bypass valve for su...

Страница 8: ...Part Number Flow Meter Size Replacement Kit Fits Meter Part Number Repair Kit Part Number 3 8 in B110 375 B110 375 1 2 B251 102 1 2 in B110 500 B110 500 1 2 B251 105 3 4 in B110 750 B110 750 1 2 B251...

Страница 9: ...y Upstream Rotor Support Retaining Ring Retaining Ring Flow Meter Body Downstream Rotor Support Retaining Ring Groove Retaining Ring Groove Magnetic Pickup Figure 7 Component positions for B110 375 B1...

Страница 10: ...otors do not contain a cast or engraved arrow However a colored cap on the downstream side of the rotor shaft indicates flow direction Remove this cap before assembly noting flow direction 1 Install o...

Страница 11: ...4 515 6000 82 981 20 330 6 6 00 in 152 40 mm B311 066 1 1 2 in 38 1 mm 2 in grooved end 5000 15 180 56 8 681 4 515 6000 82 981 20 330 6 6 00 in 152 40 mm B111 120 2 in 50 8 mm 2 in female NPT 5000 40...

Страница 12: ...monitor Move to location where meter is full on startup or add down stream flow control valve Erratic indication at low flow good indication at high flow Rotor has foreign material wrapped around it C...

Отзывы: