Badger Meter 340 MB Btu Series Скачать руководство пользователя страница 10

10

Communication Port
RS-485 with termination, pull up and 

pull down jumpers

Operating Temperature
  0° C to +70° C
  32° F to +158° F

Storage Temperature
  -40° C to +85° C
  -40° F to +185° F

Weight
  4 .8 oz . with connector headers 

installed

SENSOr CALIBrATION
Badger Meter
 
  Use K and Offset provided in sensor 

owner’s manual

Other Sensors
   Check with factory

uNITS OF MEASurE
Flow measurement
Rate: 
  gpm, gph, l/sec, l/min, l/hr, ft3/sec, 

ft3/min, ft3/hr, m3/sec, m3/min, m3/hr

Total: 
  gallons, liters, cubic feet, cubic 

meters

Energy measurement
Rate
  kBtu/min, kBtu/hr, kW, MW, hp, tons
Total
  Btu, kBtu, MBtu, kWh, MWh, kJ, MJ 
Temperature units 
  Fahrenheit, Centigrade

PrOGrAMMING

Requires PC or laptop running 
Windows

®

 2000, XP

Badger Meter Model 340BN 
programming kit containing software 
and Model A-301 programming cable is 
required for programming and setup

SPECIFICATIONS

Power

Power supply options:
  12-24 VAC rms Tolerance 

12-24 VDC Tolerance

Current draw: 
  < 70mA @ 12 VDC

Flow Sensor Input
Pulse type sensors:
  Signal amplitude:
    2 .5 VDC threshold
  Signal limits: 
    Vin < 35V  (DC or AC peak)
  Frequency:
    0-10kHz
  Pull-up:
    15 VDC @ 2 k

 Source Impedance

Sine wave sensors:
  Signal amplitude:
    30 mV p-p threshold
  Signal limits:
    Vin < 35V  (DC or AC peak)
  Frequency:
      0-10kHz

Power out terminal
  Excitation voltage 3 wire sensors:
    15 VDC @ 500

 Source Impedance

Temperature Sensor Input
2 required:
  10 k

 thermistor, 2 wire, type II,     

10 k

  @ 25°C

  100

 platinum RTD, DIN  

 

  calibration curve, conforms to  

 

    IEC-751 Standard
  1000

  platinum RTD, DIN  

 

  calibration curve, conforms to  

 

    IEC-751 Standard
  calibration range 0-150°C

Metal Enclosure dimensions

Plastic Enclosure dimensions

PRELIMINARY

Содержание 340 MB Btu Series

Страница 1: ...BadgerMeter Inc Installation Operation Manual Model 340MB Modbus Energy Transmitter PN 820035 12 07 PRELIMINARY...

Страница 2: ...ements and produce accurate drift free outputs The Model 340MB is configured using Badger Meter Windows based programming software Calibration information for the flow sensor units of measurement and...

Страница 3: ...through its mounting holes After wiring the transmitter may be attached to the enclosure with the terminal headers facing inwards using the slots in the mounting flanges As an alternate mounting arra...

Страница 4: ...Model 340MB Sensor Input Signal terminal and connect the flow sensor black wire to Model 340MB Sensor Input Signal terminal The bare wire connects to the Sensor Input Shield terminal SDI Series standa...

Страница 5: ...m the flow sensor termed temperature sensor T2 should be connected to terminal block Temp 2 Connecting the Modbus Buss As shown in the Modbus Sample Wiring Diagram the position of jumpers on each 340M...

Страница 6: ...rt taking care to properly align the tab on the plug and socket to maintain polarity Plug the Model DB9 connector on the opposite end of the Model A301 cable to an available PC communications port If...

Страница 7: ...tual changes in flow and energy A scale of 0 10 is used with 10 providing the greatest degree of smoothing Step 1 Select the flow sensor type and enter the K and Offset values See Note 1 Step 6 Select...

Страница 8: ...us network as outlined below 1 Connect the PC to the Model 340MB transmitter using the Badger Meter Model A301 communications cable Plug the RS232 connector on the Model A301cable to the 340MB socket...

Страница 9: ...oat R W Temperature Calculation Mode 18 IEEE754 Float R W Flow Filter Coefficient 20 IEEE754 Float R W Temperature Filter Coefficient 22 IEEE754 Float R W Specific Heat Capacity 24 IEEE754 Float R W F...

Страница 10: ...del 340BN programming kit containing software and Model A 301 programming cable is required for programming and setup SPECIFICATIONS Power Power supply options 12 24 VAC rms Tolerance 12 24 VDC Tolera...

Страница 11: ...11 This page intentionally left blank PRELIMINARY...

Страница 12: ...Street Tulsa Oklahoma 74112 918 836 8411 Fax 918 832 9962 www badgermeter com Please see our website at www dataindustrial com for specific contacts Copyright Badger Meter Inc 2007 All rights reserved...

Отзывы: