Badger Meter 228 Series Скачать руководство пользователя страница 9

9

SpeciḀcations

Wetted Materials (except tees) 

•  See Ordering Matrix

Sensor Sleeve and Hex Adapter for 228BR, 228CB, 

•  Sleeve: Admiralty Brass, UNS C44300; Hex Adapt

-

er: Valve Bronze, UNS C83600

Sensor Sleeve and Hex Adapter for 228SS and 

228CS

•  Series 300 Stainless Steel

Tee for 228B

•  Cast Bronze, Class 125 Per ASME B16.15, and 

Copper Coupling

Tee for 228SS

•  Cast 316 Stainless, Class 150

Tee for 228CB and 228CS

•  Cast Iron, Class 125 Per ASME B16.4

Tee for 250B

•  Cast valve bronze, UNS C83600

 Temperature Ratings

•  Standard Electronics - 221 deg. F (105 deg. C)
•  Irrigation Electronics - 150 deg. F (66 deg. C)

Pressure Ratings
 

 

At 100°F   

At 221°F

 

250BR 

400 psi 

 

325 psi

 

228B 

200 psi 

 

165 psi

 

228CB 

175 psi 

 

140 psi

 

220SS 

400 psi 

 

325 psi 

Recommended design Flow Range

•  0.5 to 30 ft/sec for 228
•  0.3 to 15 ft/sec for 250B

Accuracy

•  ± 1.0% of full scale over recommended design flow 

range for 228

•  ± 1.0% of rate for 250

Repeatability

•  ± 0.3% of full scale over recommended design flow 

range for all except 250B

•  ± 0.7% of full scale over recommended design flow 

range for 250B

Linearity

•  ± 0.2% of full scale over recommended design flow 

range for all except 250BR

•  ± 0.7% of full scale over recommended design flow 

range for 250BR 

Transducer Excitation

•  Quiescent current  [email protected] to 35.0VDC 

max.

•  Quiescent voltage (V

high

   

Supply Voltage -(600uA*Supply impedance)

•  ON state (V

Low

)  Max. 1.2VDC@40mA current limit 

(15ohm+0.7VDC)

Output Frequency

•  3.2 Hz to 200 Hz for all except 250BR
•  0.8 Hz to 80 Hz for 250BR

Output  Pulse Width

•  5 msec ±25%
•  Square wave between 100Hz to 200Hz limit

Electrical Cable for Standard Sensor Electronics

•  20 feet of 2-conductor 20 AWG shielded U.L. type 

PTLC wire provided for connection to display or 
analog transmitter unit.  Rated to 105 deg. C.  May 
be extended to a maximum of 2000 feet with similar 
cable and insulation appropriate for application.

Electrical Cable for IR Sensor Electronics

•  48 inches of U.L. Style 116666 copper solid AWG 

18 wire with direct burial insulation.  Rated to 105 
deg. C.

Содержание 228 Series

Страница 1: ...Installation Operation Manual BadgerMeter Inc Badger Series 250 228 Flow Sensors Metal Tee Type Impeller Flow Sensors 872021 Rev 6 4 09...

Страница 2: ...ssembly shaft and O rings are replaceable in the field Badger Meter flow sensors feature a closed six bladed impeller design using a proprietary non magnetic sensing technology The forward swept impel...

Страница 3: ...degrees from top dead center The sensor should never be located at the bottom of the pipe as sediment may collect there Locations off top dead center cause the impeller friction to increase which may...

Страница 4: ...r com 1 DO NOT remove the plastic caps from the sensor leads until ready to splice 2 Use a twisted pair cable suitable for direct burial to connect the sensor to the transmitter monitor or con troller...

Страница 5: ...rdous area The referenced installation drawing shows such apparatus located in a non hazardous location Proper interfacing between the hazardous and non hazardous areas must be pro vided It is of abso...

Страница 6: ...6...

Страница 7: ...S20xx xxxx 1 99 2 747 0 10 100 250BR05xx xxxx sch40 PVC none 0 337379 0 097041 0 8 8 sch80 PVC none 0 338073 0 134854 0 8 8 sch40 steel none 0 356212 0 075729 0 8 8 Type L none 0 350899 0 321666 0 8 8...

Страница 8: ...haft Replacement 10 Install the sensor into the 2 NPT adapter or tee so that alignment hole is facing upstream and flow ar rows point in the direction of the actual flow Since the positioning collar w...

Страница 9: ...epeatability 0 3 of full scale over recommended design flow range for all except 250B 0 7 of full scale over recommended design flow range for 250B Linearity 0 2 of full scale over recommended design...

Страница 10: ...the sensor input termi nals ON and OFF repeatedly allows the display to respond by trying to calculate a flow rate for the frequency of your shorting action If the display does not show a change from...

Страница 11: ...11 This page intentionally left blank...

Страница 12: ...o change product or system specifications without notice except to the extent an outstanding contractual obligation exists BadgerMeter Inc Copyright Badger Meter Inc 2009 All rights reserved Badger an...

Отзывы: