PAGE 22
SECTION 14:
ELECTRICAL SYSTEM
This mower is equipped with three protective
fuses: a 25-amp main fuse, a 10-amp PTO fuse
(blade engagement) and a 15-amp linear
actuator fuse (optional deck lift). The main fuse is
located by the starter solenoid. The PTO fuse is
located just underneath the control panel along
with the linear actuator fuse (If equipped).
A blown fuse usually indicates a problem within
the electrical system or an electrical component.
Never replace a fuse with one of a higher
amperage rating or "bypass" a fuse in any way.
Doing so creates a significant fire hazard and can
cause severe damage to the mower's electrical
components. If a fuse is repeatedly blowing,
contact your Bad Boy dealer.
In order to access the PTO fuse, you will need to
take off the control panel by removing control
panel screws using a 1/8" hex bit.
Battery
Terminals
Main Fuse
(25 Amps)
PTO Fuse
(10 Amps)
Starter
Signal Wire
Starter
Solenoid
Control Panel
Screws
Fig. 18