Need help? 1.800.762.1142
Do not return to place of purchase.
Recipes
BlueRhino.com/recipes
Replacement Parts
parts.BlueRhino.com /
1.800.762.1142
9
Installing LP Gas Tank
To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads.
W
CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
grill.
Insert and secure LP Gas Tank
Place precision-filled LP gas tank upright into the notches in the right cart frame so the tank
valve is facing the gas line connection.
Secure tank by sliding the tank retainer wire over shoulder of LP gas tank.
Connecting LP Gas Tank
1. Before connecting, be sure there is no debris caught
in the head of the LP gas tank, head of the regulator
valve or in the head of the burner or burner ports.
2. Connect regulator/hose assembly to tank by turning
knob clockwise until it stops.
disconnecting LP Gas Tank
1. Before disconnecting, make sure the LP gas tank valve
is “CLOSED.”
2. Disconnect regulator/hose assembly from LP gas tank
by turning knob counterclockwise until it is loose.
W
CAUTION: LP gas tank must be properly
disconnected and removed prior to
moving this grill.
3. Place the protective cap cover on the LP tank and
store the tank outdoors in a well-ventilated area out of
direct sunlight.
Getting More Propane
Need a tank of gas? One option is to try propane exchange. It’s easy, fast, safe, and available
at tens of thousands of conveniently located retail outlets nationwide, which are typically open
nights and weekends. You can purchase a fresh, precision-filled tank or
exchange your empty for a fresh, precision-filled tank. Another option is
to have your tank refilled at a refill station. Be sure to check the hours of
operation for the refill station.
20 lb
9 Kg
17.9 in.
/ 45.5 cm
12.2 in. / 31 cm
Operating Instructions
Checking for Leaks
Burner Connections
1. Make sure the regulator valve and hose
connections are securely fastened to the burner
and the tank.
2. Visually check the connection between the
burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the
orifice.
W
WArNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion
which can cause death, serious bodily
injury or damage to property.
4. Please refer to diagram for proper installation
(Figure 1).
5. If the burner/venturi tube does not rest flush to the
orifice, as shown, please contact 1.800.762.1142
for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak detection solution by mixing
one part liquid dishwashing soap with three parts
water.
2. Make sure control knobs are in the “ OFF”
position (Figure 2).
3. Connect LP gas tank per “Installing LP Gas Tank”
section.
4. Turn LP gas tank valve to “OPEN.”
5. Spoon several drops of solution, or use a squirt
bottle, at all “X” locations (Figures 1 and 3).
a. If any bubbles appear, turn LP gas tank valve to
“CLOSED,” reconnect and re-test.
b. If you continue to see bubbles after several
attempts, turn LP gas tank valve to “CLOSED”
and disconnect LP gas tank, per “Disconnect LP
Gas Tank” section. Contact 1.800.762.1142 for
assistance.
c. If no bubbles appear after one minute, turn
LP gas tank valve to “CLOSED,” wipe away
solution and proceed.
Operating Main Burners
First Use
1. Make sure all labels, packaging and protective
films have been removed from the grill.
2. Remove manufacturing oils before cooking on this
grill for the first time by operating the grill for at
least 15 minutes on (HIGH) with the lid closed.
This will “heat clean” the internal parts and
dissipate odors.
Lighting
W
CAUTION: Keep outdoor gas cooking appliance area clear and free
from combustible materials, gasoline and other flammable vapors and
liquids.
W
CAUTION: do NOT obstruct the flow of combustion and ventilation air.
W
CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
W
CAUTION: Attempting to light the burner with the lid closed may cause
an explosion.
1. Open lid.
2. Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3. All control knobs must be in the “ OFF” position (Figure 2).
4. LP gas tank per “Installing LP Gas Tank” section.
5. LP gas tank valve to “OPEN.”
6. Push and turn control knob to (HIGH). The burner should light. Repeat up to three times.
7. If ignition does not occur in 5 seconds, turn burner control knob “ OFF,” wait 5 minutes,
and repeat lighting procedure.
8. If igniter does not light burner, use a lit match secured with the lighting rod (included with
grill) to light burners. Access the burners through the cooking grid and heat plates. Position
lit match near side of burner (Figure 4).
Figure 1: Main Burners
LP Gas Valve
with Orifice
Valve
Soft Pipe
Connection
Burner/
venturi
tube
Figure 2
OFF
ARRÊT
Figure 3
X
X
X
X
X
Figure 4
Lighting
Rod
Match