IMPORTANT SAFETY INFORMATION 

 

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas 
Code, ANSI Z223.1/NFPA 54; International Fuel Gas Code. ; Natural Gas and Propane Installation Code, 
CSA B149.1; or Propane Storage and Handling Code, B149.2, as applicable. 
 
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system 
during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa). 
 
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve 
during any pressure testing of the gas supply system at test pressure equal to or less than 1/2 psi (3.5kPa). 
 
The appliance area must be kept clear and free from combustible materials, gasoline and other flammable 
vapors and liquids.   
 
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to 
inspect the appliance and to replace any part of the control system and any gas control which has been under 
water. 
 

Children and adults should be alerted to the hazards of high surface temperatures and kept at a safe 
distance to avoid burns or clothing ignition. 
 
Young children should be carefully supervised when they are anywhere near the appliance.   
 
Clothing or other flammable material should not be hung from the appliance, or placed on or near the 
appliance. 
 
Any screen or guard removed for servicing an appliance must be replaced prior to operating the 
appliance. 
 
Installation and repair should be done by a qualified service person. The appliance should be 
inspected before use and at least annually by a professional service person. More frequent cleaning 
may be required as necessary. It is imperative that the control compartments, burners and circulating 
air passageways of the appliance be kept clean. 

 
Do NOT burn solid fuels in this gas fireplace. 
 
Do NOT ignite the burner before pouring all of the burner media (lava rock or fire ice) into the burner pan. The 
media must be evenly distributed over the burner. 
 
During initial firing of firepit, please stay away from the firepit for 20 minutes as fire media (lava rock or fire ice) 
may pop and hit someone on the face or eyes 
 
Do NOT ignite or use the firepit if the burner media (lava rock or fire ice) are wet. Ensure the burner media are 
completely dry before igniting as intense heat could cause the media to crack and pop. 
 
It is UNSAFE to use this product for cooking! 
 

CAUTION

: The propane gas pressure regulator provided with this appliance must be used. This regulator is 

set for an outlet pressure of 11 inches water column. 
 
This outdoor gas appliance is not intended to be installed in or on recreational vehicles and/or boats. 
 
Before each use of this gas appliance, open the LP (Liquid Propane) Tank Drawer and inspect the LP Hose. If 
there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced prior to the gas 
appliance being put into operation. Use only the replacement hose assembly specified in this manual. Inspect 
the burner before each use of the appliance. The burner must be replaced prior to the appliance being put 
into operation if it is evident that the burner is damaged. Use only the burner listed in these instructions.   
 
Keep the fuel supply hose away from any heated surfaces. 

Содержание ARV06300

Страница 1: ...oper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment FOR USE WITH 20LB 9KG PROPANE CYLINDER WITH TYPE 1 CONNECTION OR FOR USE WITH NATURAL GAS AFTER CONVERSION KIT IS INSTALLED MUST BE PROFESSIONALLY INSTALLED Sep 31 2014 Installer Leav...

Страница 2: ...nt Safety Information 3 Important About Propane 4 Specification 4 Parts Identification List 5 6 Installation 7 11 Natural Gas Conversion 12 Lighting Instructions 13 Batteries 14 Maintenance 14 Troubleshooting Guide 15 Warranty 16 ...

Страница 3: ...qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required as necessary It is imperative that the control compartments burners and circulating air passageways of the appliance be kept clean Do NOT burn solid fuels in this gas fireplace Do NOT ignite the burner before pouring all of the burner m...

Страница 4: ... in a well ventilated space and shall not be used in a building garage or any other enclosed space When this appliance is not is use the gas must be turned off at the supply cylinder Storage of this appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance Cylinders must be stored outdoors in a well ventilated area out of the reach of children Disconnecte...

Страница 5: ...P1330 1 F GAS TUBE FP1689 1 G ORIFICE ELBOW FP1385 1 H IGNITION MODULE FP1666 1 I ORIFICE BRACKET FP1667 1 J PROPANE ORIFICE FP1299 1 K NATURAL GAS ORIFICE FP1300 1 L AAA BATTERY 1 5V HW0705 1 M FOOTCAP FC0660 4 N HEX BOLT DRIVER HW0006 1 O 1 4 X 18 MM BOLT HW0035 8 P 1 4 X 30 MM BOLT HW0038 10 Q WASHERS HW0004 14 R BIG WASHERS HW0594 4 S FIREPIT TABLETOP FP1672 1 ...

Страница 6: ...3 1 U BOTTOM PANEL FP1674 1 V BACK PANEL FP1675 1 W DOOR PANEL FP1676 1 Y BURNER COVER FP1677 1 Z BURNER COVER PROTECTIVE RING FP1678 1 AA FIREPAN BURNER ASSEMBLY FP1679 1 BB SUPPORT BAR 1 FP1680 1 CC SUPPORT BAR 2 FP1681 1 ...

Страница 7: ...ls and set parts on a flat non abrasive surface IMPORTANT NOTE WE RECOMMEND TWO PEOPLE WORK TOGETHER TO ASSEMBLE THE PRODUCT 2 Place the back panel upside down on a flat non abrasive surface Open it as shown in Figure 2 Figure 2 3 Assemble the door panel to the back panel as shown in Figure 3 Figure 3 ...

Страница 8: ...30 mm bolts and washers as shown in Figure 4 Guide the bolts through holes in the bottom panel into pre drilled holes in the legs Hand tighten only Figure 4 5 Carefully place the middle panel inside back panel with bottom panel as shown in Figure 5 Figure 5 ...

Страница 9: ...rilled holes in the back panel Hand tighten only Figure 6 7 Attach two support bar to the firepan burner assembly by using two 1 4 x30 mm bolts and washers as shown in Figure 7 Hand tighten only Figure 7 8 Attach the complete firepan burner assembly to back panel with door panel by using four 1 4 x18 mm bolts and washers as shown in Figure 8 Hand tighten only Figure 8 ...

Страница 10: ...over protective ring inside table top Figure 9 11 Open the tank door place the tank in the holder and connect the regulator as shown in Figure 10 Screw the black handle clock wise to tighten Turn the handle counterclock wise to remove The hose must point down Open the control door and check that the valve is turned all the way clockwise to the OFF position Open the tank valve Apply a solution of s...

Страница 11: ... cardboard cover from the ignition well as shown in Figure 12 Remove any lava rock or fire ice on top of ignition well Figure 13 CARDBOARD COVER 15 Open the tank valve Apply a solution of soapy water to the tank regulator connection and to the valve hose connection to check for leaks as shown in Figure 14 If soap bubbles continue to form the connection has a leak If a leak is found close the tank ...

Страница 12: ...p 4 Disconnect the orifice from the elbow and replace it with the Natural Gas orifice from the kit Re fit the orifice bracket assembly onto the holder using the 2 M4 screws and nuts Re connect the aluminum gas tube into the end of the elbow Connect your Natural Gas supply line onto the gas valve at the control panel BEFORE ATTEMPTING TO USE THE FIREPIT check ALL of the connections for leaks using ...

Страница 13: ...the igniter button pushed in push and turn the control knob to the ON position the fire should light within a few seconds Once the flame is lit release the igniter button and continue to hold the Serial Number _________________ Model Number 98300 CAUTION The gas pressure regulator provided with this appliance must be used This regulator is set for an outlet pressure of Minimum clearance from combu...

Страница 14: ...afely May explode or leak if charged or disposed of in fire Make sure of the polarity Mercury and cadmium free Always purchase the correct size and grade of battery most suitable for the intended use Replace all batteries of a set at the same time Clean the battery contacts and also those of the device prior to battery installation Ensure batteries are installed correctly with regard to polarity a...

Страница 15: ...Check that the electrode is not cracked or broken Burner won t light Lack of oxygen Remove excess lava rocks or fire ices from around the ignition well Thermocouple not in flame Check that the tip of the thermocouple is even with the top of the ignition well Remove any lava rocks from the ignition well Thermocouple connection at the main control valve is loose Tighten the thermocouple nut at the b...

Страница 16: ...rranty is subject to the exclusions set forth above In addition the following are excluded from coverage under this warranty any item used for commercial contract or any other non residential purpose clearance items display models or items purchased as is freight damage items subject to misuse abuse neglect or lack of proper care or maintenance including without limitation as provided in any care ...

Страница 17: ...17 that limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state ...

Отзывы: