8
9
Connect the
Hose
and
Regulator
to the LP cylinder. The LP
cylinder is sold separately. Use a standard 20 lb. propane
cylinder only. Lift the
Cylinder Housing
and rest it on the top of
the
assembled
Support Brackets
.
Attach
Regulator
to valve on LP cylinder and hand tighten securely.
Place LP tank onto base of heater and lower
Cylinder Housing
.
NOTE: Use this heater only with a propane vapor withdrawal
supply system. See Chapter 5 of the standard for storage and
handling of liquefied petroleum gas, ANSI/NFPA 58. Your local
library or fire department should have this book.
9
A minimum supply pressure of .5 psi is required for the purpose of input adjustment of propane gas. Storage of an appliance
indoors is permissible only if the cylinder is disconnected and removed from the appliance. A cylinder must be stored
outdoors in a well-ventilated area out of the reach of children. A disconnected cylinder must have dust caps tightly installed
and must not be stored in a building, garage, or any other enclosed area. The minimum permissible gas supply pressure of 11
W.C. is required for purpose of hose adjustment. The minimum hourly of 17,500 BTU is required input rating for a heater for
automatic operation rating less than full input rating.
The pressure regulator and hose assembly supplied with the appliance must be used.
The installation must conform with local codes, or in the absence of local codes, with national fuel gas code, ANSI Z223.1/
NFPA54, natural gas and propane Installation Code, CSA B149.1, or propane storage and handling code, B149.2
A dented rusted or damaged propane cylinder may be hazardous and should be checked by your local cylinder supplier.
Never use a propane cylinder with a damaged valve connection.
The propane cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S.
Department of Transportation (DOT) or the standard for cylinders, spheres and tubes for transportation of dangerous goods
and commission, CAN/CSA-B339.
•
The cylinder must have a listed overfilling prevention device.
•
The cylinder must have a connection device compatible with
the connection for the appliance.
•
The cylinder used must include a collar to protect the
cylinder valve.
•
Never connect an unregulated propane cylinder to the
heater.
•
Do not store a spare LP-gas cylinder under or near
this appliance.
•
Never fill the cylinder beyond 80 percent full.
•
Place the dust cap on the cylinder valve outlet
whenever the cylinder is not in use. Only install
the type of dust cap on the cylinder valve that is
provided with the cylinder valve. Other types of
caps or plugs may result in leakage of propane.
ASSEMBLY
Contact us for assistance: