4X”- 6” Deringer 20/30 Maintenance Instructions
BD-INST-02030 | Rev C | 12/22/2015 | Copyright 2011 Backflow Direct, LLC
Removing Access Port Cover Plate
1.
Using a 15/16
” socket wrench loosen all eight bolts on the access port
cover plate (A).
2.
Remove bolts and tapered washers (B) and store in a safe place. Be
careful not to lose tapered washers as the access cover will not seal
properly without the tapered washers.
3.
Remove access port cover plate (C). Do not remove Access Port O-ring
(D).
B
C
A
BD-INST-4X2030 | Rev A | 09/06/2019 | Copyright 2011 Backflow Direct, LLC
Page 5 of 20