Tru Pointe® Ultra
Instruction 0028-9000
2
2 Introduction
General Description
The Tru Pointe® Ultra HD Ultrasonic Leak Detector is an electronic instrument that detects the
inaudible high frequency sound (ultrasound) of high pressure leaks and converts it to sound a
human can hear. Using patented technology, the Tru Pointe® Ultra guides the user to a leak by
quantifying the intensity of the ultrasound and converting it to sound the user can easily hear.
The Tru Pointe® Ultra HD has been speci
fi
cally designed for air conditioning and refrigeration
(HVAC-R) leak detection. The Tru Pointe® Ultra HD is the only test system that can simultane-
ously detect the vacuum and high pressure leaks that can occur in HVAC-R systems. Since
the instrument detects only sound, it is gas-independent and can be used to detect leaks at the
speed of sound, without the delay seen with gas dependent “sniffers.”
What’s in the Kit
0028-8001
Tru Pointe
®
Ultra HD Kit
Tru Pointe® Ultra ...................... 0028-7000
Instruction Manual .................... 0028-9001
Carrying Case........................... 0028-0005
6” Wave Guide .......................... 0028-0004
Touch Probe ............................. 0028-0003
Noise Attenuating Heavy
Duty Headset ............................ 0028-0011
9v Battery ................................. 0204-0024
Warranty Card .......................... 0006-8825
0028-8011
Tru Pointe
®
Ultra HD Kit w/
SoundBlaster
®
Tru Pointe® Ultra HD ................ 0028-7000
SoundBlaster® ......................... 0028-7006
Instruction Manual .................... 0028-9001
Carrying Case........................... 0028-0005
6” Wave Guide .......................... 0028-0004
Touch Probe ............................. 0028-0003
Noise Attenuating Heavy
Duty Headset ............................ 0028-0011
9v Battery ................................. 0204-0024
Warranty Card .......................... 0006-8825
Features
•
Capable of detecting a 5 psi leak from a .005” hole from 20-30 feet (depending on back-
ground noise.
•
Capable of detecting any gas that generates ultrasonic sound during
fl
ow, including vacuum
leaks.
•
Not affected by wind or high concentrations of leaked refrigerants.
•
SoundBlaster® allows testing of items not under pressure. (0028-8011 only)