background image

Tru Pointe® Ultra

Instruction 0028-9000

8

Using the SoundBlaster

®

Some Tru Pointe

®

 Ultra HD kits include Bacharach’s ultrasonic sound generator, the SoundBlast-

er

®

.  The SoundBlaster

®

 is used to arti

fi

 cially pressurize items and detect potential leaks using a 

115dB ultrasonic tone.  The Tru Pointe

®

 Ultra HD can detect the tone as it escapes in areas that 

are not under pressure.

To use the SoundBlaster

®

:

1. 

Press the On/Off Button once on the SoundBlaster

®

.

2. 

Place the SoundBlaster

®

 inside the item to be tested.

3. 

Use the Tru Pointe

®

 Ultra HD to detect the leaked ultrasonic waves generated by 

the SoundBlaster

®

 using the same method as detecting a standard airborne leak.

NOTE:

  Using the SoundBlaster

®

 inside a symmetrical 

object (i.e. a cylindrical tank) can cause standing waves, 
which can result in hot and cold spots.  For these situa-
tions push the ‘Mode’ button to turn the SoundBlaster

®

’s 

burst mode on.

Tips on Use:

1. 

Sound waves lose strength with distance, so when checking a building for leaks, 
do not place the SoundBlaster

®

 in the basement and attempt to 

fi

 nd leaks in the 

roof.

2. 

It is best to remove the nose cone from the SoundBlaster

®

 when checking roofs

3. 

If the SoundBlaster

®

’s tone is too strong, place a piece of sponge or foam in the 

nose cone.

4. 

DO NOT place the nose cone 

fl

 at on a hard surface, as the re

fl

 ection of the gener-

ated sound could damage the SoundBlaster

®

.

Содержание Tru Pointe Ultra HD

Страница 1: ...Tru Pointe Ultra HD Ultrasonic Leak Detector Instruction 0028 9001 Operation and Maintenance Rev 1 May 2010 The Measurable Difference...

Страница 2: ...warranty of Seller Bacharach warrants that this product conforms to the Product Description contained in this literature Bacharach makes no other warranty whether expressed or implied including warra...

Страница 3: ...8011 2 Features 2 3 Specifications 3 4 Operation 4 Physical 4 Taking Readings 4 General 4 Airborne Leak Detection 5 Operating Tips 6 Electrical Arcing 6 Electrical Corona 6 Using the Touch Probe 7 The...

Страница 4: ...NOTES...

Страница 5: ...G and the warning symbol at left in this manual denotes a potential hazard associ ated with the use of this equipment It calls attention to a procedure practice or condition or the like which if not c...

Страница 6: ...to detect leaks at the speed of sound without the delay seen with gas dependent sniffers What s in the Kit 0028 8001 Tru Pointe Ultra HD Kit Tru Pointe Ultra 0028 7000 Instruction Manual 0028 9001 Ca...

Страница 7: ...Connector 3 5 mm Stereo Weight 0 3 lb 138 g including battery Electrical Sensitivity 80 db V bar Ultrasound Converter Type Heterodyne Frequency Response 34kHz to 42kHz Heterodyne Oscillator Analog He...

Страница 8: ...he detector 2 Slide the Sensitivity Adjust toward the top of the instrument until it stops The Tru Pointe Ultra HD is now at full sensitivity NOTE Always begin testing at full sensitivity and adjust a...

Страница 9: ...reduce the sensitivity until the LED s disappear 2 While pressing the On Off Button scan the area of the suspected leak in a side to side motion 3 While scanning listen to differences in the sounds d...

Страница 10: ...electronic devices Place your body between the source of the sound and the leak point Electrical Arcing Electrical arcing is an electric current flow in air and can be a very destructive and dangerous...

Страница 11: ...from the Tru Pointe Ultra HD 2 Screw the Touch Probe onto the sensor 3 The Tru Pointe Ultra HD is now ready to detect solid borne sound Thermal Expansion Valves TXV The following steps can be used to...

Страница 12: ...y the SoundBlaster using the same method as detecting a standard airborne leak NOTE Using the SoundBlaster inside a symmetrical object i e a cylindrical tank can cause standing waves which can result...

Страница 13: ...aks with the Tru Pointe Ultra around the perimeters of the doors and windows 3 If the Tru Pointe Ultra HD reading is at 10 reduce the sensitivity until the detector reads 4 5 and begin scanning again...

Страница 14: ...e the batteries use only high quality 9 volt alkaline for both the Tru Pointe Ultra HD and the SoundBlaster and use the following instructions 1 Hold the unit with the Battery Door facing up 2 Press l...

Страница 15: ...11 Tru Pointe Ultra Instruction 0028 9000 NOTES...

Страница 16: ...The Measurable Difference Bacharach Inc Phone 724 334 5000 Toll Free 800 736 4666 Fax 724 334 5001 www mybacharach com help mybacharach com...

Отзывы: