Introduction
Halogen Monitor
4
Instruction 3015-4584 Rev 9
1.10 Specifications
Product Type ......................... Portable refrigerant gas monitor
Gas Library:
CFC:
R-11, R-12, R-113, R-114, R-502, HFP
HFC:
R-404a (HP62), R-407a, R-407c (AC9000), R-134a, R-410a (AZ20),
R-507 (AZ50), R-508b (SUVA95), R236FA, R125, R245Fa, R422a, R422d,
R427a, R424a, R426a and R438a
HCFC:
R-22, R-123, R-124, R-500, R-503, R-401a (MP39), R-402a (HP80), R-402b
(HP81), R-408a, R-409a, R-23, R21, R227
HALON:
H1301,H2402, H1211, H1234YF
Other:
FA188, FC72, N1230
Measuring Range .................. All gases 0 to 10,000 ppm
Warm-Up Time ...................... 5 minutes (300 seconds)
Detector Type ........................ Infrared, Non-Dispersive
Sensitivity .............................. 1 ppm
Accuracy................................ ±1 ppm ±10% of reading from 0-1000 ppm
(For R11, R22, R113: ±10 ppm ±15% of reading from 0-1000 ppm)
Response Time ..................... 90% of response within 5 seconds; 100% in 7 seconds
Temperature Drift .................. 1.5 ppm per °C between purge cycles
System Noise ........................ Less than 40dB (A) at 10 ft (3 m)
Operating Temperature ......... 32 to 122°F (0 to 50°C)
Ambient Humidity .................. 5 to 90% RH (non-condensing)
Altitude Limit .......................... 6,562 ft (2,000 m)
Power .................................... DC power pack, provides 8–12 hours of operation
Power Consumption .............. 15 Watts maximum
Front panel ............................ 3 indicator lights:
ON
Green LED flashes during warm-up, then glows steadily during
normal operation
FAULT
Yellow LED flashes when there is a system fault
ALARM
Red LED flashes when the gas level is above its alarm setting
Audible Alarm ........................ Internal audible alarm programmable for any of the following conditions:
OFF, FAULT/ALARM, ALARM
Dimensions (D x L x W)......... 9.0 x 14.5 x 5.0 inches (229 x 368 x 127 mm)
Weight ................................... Less than 9 lbs (4 kg) including battery
Valid Calibration Period
to Specifications .................... 12 months
Warranty ................................ 2 years from date of shipment