3015-9005 Rev 1 

5.2.  Limited Warranty 

The purchaser is warranted that this leak 

detector will be free of defects in material 

and workmanship for 3 years from date 

of purchase.  This warranty does not 

cover sensors, reference leaks, filters, 

airflow balls, lamps, batteries, or probe 

tips. Damages caused by the user will not 

be covered. 
If any defects are discovered during the 

warranty period, an Authorized Service 

Center will repair or replace the unit at 

their option.  The foregoing limited 

warranty is exclusive and in lieu of all 

other warranties,  whether written or 

implied, and no warranty of 

merchantability or fitness for purpose will 

apply. 

5.3.  Repair Information 

Should it become necessary to repair your 

H-10 Pro, please contact an authorized 

service center.  Units should be carefully 

packed to prevent shipping damage and 

shipped prepaid. 

www.

.com

[email protected]

1.800.561.8187

Содержание H-10 PRO

Страница 1: ...3015 9005 Rev 1 1 Instruction Manual P N 3015 9005 Revision 1 March 2016 Product Leadership Training Service Reliability www com information itm com 1 800 561 8187...

Страница 2: ...Bacharach Inc WARNING This product is considered to be Group 1 Class A equipment as defined by EN 55011 standards and is suitable for use in industrial environments There may be potential difficultie...

Страница 3: ...g ASHRAE A2 or A3 rated refrigerants HAZARDOUS AREA WARNING This instrument has not been designed to be intrinsically safe for use in areas classified as hazardous locations For your safety DO NOT 1 3...

Страница 4: ...uce the life or destroy the sensor Life of the sensor is directly proportional to the amount of refrigerant that it is exposed to C Exposure to high concentrations of refrigerant may require adjustmen...

Страница 5: ...Conditions 32 to 104 F 0 to 40 C Approvals CE Warranty 3 years 1 Based on normal use Consistent and or constant exposure to high levels of refrigerant will deteriorate the sensor life more quickly In...

Страница 6: ...alse alarming while retaining superior sensitivity for pinpointing the most difficult to find refrigerant leaks A pump inside the unit draws air through the probe to the sensor The presence of refrige...

Страница 7: ...3015 9005 Rev 1 7 2 2 Panel Controls www com information itm com 1 800 561 8187...

Страница 8: ...time is 3 4 hours or until the Full Charge LED turns green 2 4 Adjusting the Sensitivity Set the Leak Size switch as follows SMALL switch position is the highest sensitivity The unit will indicate lea...

Страница 9: ...large leaks of any refrigerant The large leak setting should be used in conjunction with manual mode 2 5 Auto Mode vs Manual Mode Auto mode enables the H 10 Pro to block out background levels of refri...

Страница 10: ...s see Section 2 4 In Manual Mode the auto zero circuit is disabled The unit will not zero the leak if the probe is held over the leak site This mode may require frequent readjustment of the Manual Bal...

Страница 11: ...xists the red ball should noticeably rise up into the probe when you uncover the probe tip Note that the actual height and final resting position of the red ball are not important If the airflow ball...

Страница 12: ...ted as combustible flammable gases e g ASHRAE A2 or A3 rated refrigerants 1 Set the range switch to the appropriate range to ensure maximum sensor life If the leak size is unknown start at the Large l...

Страница 13: ...shop air set the unit on the small leak sensitivity and double check equipment for small leaks After locating and repairing any leaks requiring the use of the LARGE switch setting switch to the MEDIUM...

Страница 14: ...tch to AUTO slide the leak switch to SMALL turn ON the unit and allow it to stabilize approximately 2 minutes 2 When stabilized at approximately 1 click per second briefly touch the probe tip to the c...

Страница 15: ...dication is meaningless during subsequent leak testing activity NOTE Check for proper heat adjustment on a daily basis This assures the H 10 Pro is calibrated for the correct sensitivity for your dail...

Страница 16: ...or wet To replace the filter follow the steps below 1 Remove the black rubber probe tip 2 Pick out the filter with a pin or tweezers A fine screen will remain in the tip of the probe nozzle behind whe...

Страница 17: ...lly clockwise make sure the reference bottle contains some refrigerant 1 Turn the leak detector OFF 2 Turn the heater adjustment to its full counterclockwise position 3 Unplug the power cord and open...

Страница 18: ...e tip 3015 0784 Check for proper pump operation Sensor exposed to excessive amounts of halogen gas Move probe to clean atmosphere for several minutes while sensor purges itself Water is in the probe T...

Страница 19: ...si If unsuccessful replace the sensor 3015 0486 Replace the filter 3015 0784 Sensor has a short circuit Replace sensor 3015 0486 Atmosphere is contaminated with excessive refrigerant gas Ventilate the...

Страница 20: ...cts are discovered during the warranty period an Authorized Service Center will repair or replace the unit at their option The foregoing limited warranty is exclusive and in lieu of all other warranti...

Страница 21: ...orth American and international plugs 3015 0895 Battery clamp cigarette adapter assembly 3015 0641 Clear probe tip 3015 0680 Rubber probe tip 3015 0486 Replacement sensor 3015 0781 Tune up kit sensor...

Страница 22: ...22 3015 9005 Rev 1 5 5 Authorized Service Centers Replacement parts and service can be obtained by contacting one of the following Bacharach Service Centers www com information itm com 1 800 561 8187...

Страница 23: ...quarters of Bacharach Inc NOTE The Directives or Harmonized Standards to which this product has been evaluated may have changed Bacharach Inc however continues to market this product under a presumpti...

Страница 24: ...24 www com information itm com 1 800 561 8187...

Отзывы: