Gas Pup
4
Instruction 55-9002
•
Bar Graph Window:
Provides a real time moving display of the natural
gas concentration to give a better ‘feel’ of when the gas level has
reached a peak. The bar graph is active only in the PPM and HI%
ranges.
•
RANGE Window:
Identifies the range in which the instrument is
currently operating. This is accomplished by means of a pointer, which
in conjunction with range-labels printed on the display overlay, define a
range for the gas reading.
•
Key:
Turns the instrument, and also the backlight, ON and OFF.
•
Key:
Changes the instrument’s function as determined by its current
operating mode, thus allowing a variety of functions to be selected with
just one pushbutton. Refer to text in this manual’s
Operating
section for
details.
Gas and Pressure Fittings
Two quick-connect fittings (Figure 3) provide convenient connections to
the gas probe and pressure hose assemblies.
The gas fitting mates with a quick-connect female plug, while the pres-
sure fitting mates with a quick-connect male plug.
Introduction
Figure 3. Gas and Pressure Fittings
Gas
Fitting
Pressure
Fitting