Bacharach Flue-Gas Sample Conditioning System Скачать руководство пользователя страница 6

Instruction 0024-9415 

Bacharach, Inc. 

7

Flue Gas Sample Conditioning System

Replacement Parts

Item Description 

Part 

No.

(Fig 3)

   

Probe:

  1 

 

Complete Assembly (w/ 11.5 in. probe tube)............. 0024-3038

 2    Probe Tubes:

   

 

 

7 in. (180 mm) ...................................................... 0024-1183

   

 

 

11.5 in. (295 mm) ................................................. 0024-1184

   

 

 

19.5 in. (500 mm) ................................................. 0024-1185

   

 

 

39 in. (1000 mm) .................................................. 0024-1186

  3 

 

Gas Hose Fitting ........................................................ 0024-0877

  4 

 

Draft Hose Fitting ...................................................... 0024-0878

 5    Probe Stop 

.................................................................. 0019-3037

 6    Thumb Screw 

............................................................. 0102-0875

  7 

 

Screw, M4 x 6mm ....................................................... 0501-3829

 8    Retaining Nut 

............................................................. 0102-3740

  9 

 

Filter (Qty. 5).............................................................. 0007-1646

   

Peltier Cooler & Power Supply:

 10 

 

Complete Assembly, Peltier Cooler & Power 

   

 

   Supply (AC Power Cord not included) ................... 0024-1179

 11 

 

Plastic End Cap .......................................................... 0106-5454

 12 

 

Filter Wadding ........................................................... 0007-1647

 13 

 

Power Supply ............................................................. 0304-1713

 14 

 

AC Power Supply Cord, 3-Wire ................................. 4998-8986

   

Condensate Pump:

 15 

 

Complete Assembly .................................................... 0024-1180

 16 

 

Reservoir  .................................................................... 0106-5453

 17 

 

Plastic Screw-On Cap ................................................ 0106-5455

 18 

 

Filter Wadding (Qty. 1) .............................................. 0024-1205

 19 

 

Plastic Cap w/ Drain .................................................. 0106-5456

   

O-Rings:

 20 

 

9 x 2 mm ..................................................................... 0105-5105

 21 

 

4 x 1.75 mm ................................................................ 0105-5106

 22 

 

50 x 3 mm ................................................................... 0105-5107

 23 

 

11 x 1 mm ................................................................... 0105-5108

Содержание Flue-Gas Sample Conditioning System

Страница 1: ...nd SO2 Water vapor is removed from the flue gas sample by passing the sample through a Peltier Cooler where the sample is chilled which in turn causes the water vapor contained in the gas sample to be removed from the sample The water that was extracted from the gas sample is then pumped out of the Peltier Cooler and into a water trap The now dry conditioned flue gas sample is then sent to its ass...

Страница 2: ...and then inserting the cooler s inlet connector ensuring first that a filter is present between the cooler and probe Attach the pump s inlet hose to the bottom of the Peltier cooler Water that is condensed from the flue gas sample will be pumped into the con densate pump s reservoir through this hose Note that the condensate pump can be placed in an upright horizontal or hanging position A magnet ...

Страница 3: ... System 4 Bacharach Inc Instruction 0024 9415 Figure 2 Equipment Setup PELTIER COOLER PROBE ASSEMBLY PUMP POWER SUPPLY 100 240 VAC 50 60 HZ Connect to Combustion Test Equipment STACK TEMP THERMOCOUPLE PRESSURE Blue FLUE GAS Yellow ...

Страница 4: ...alyzer as described in its in struction manual Then insert the probe into the flue stack and begin testing During the combustion test the condensed water vapor from the flue gas will accumulate inside the pump s reservoir If the water level be gins to approach the ends of the tubes inside the reservoir then stop the test and empty the reservoir as described in the Maintenance Section of this manua...

Страница 5: ...ARNING The condensed water will be warm and slightly acidic Take all necessary precautions to prevent the water from splashing into your eyes or contacting your skin Empty the pump s reservoir Figure 3 Item 15 by first holding the pump with its reservoir facing downwards Then twist the reservoir 90 degrees either clockwise or counterclockwise to free it from the pump base Empty the reservoir then ...

Страница 6: ... 0875 7 Screw M4 x 6mm 0501 3829 8 Retaining Nut 0102 3740 9 Filter Qty 5 0007 1646 Peltier Cooler Power Supply 10 Complete Assembly Peltier Cooler Power Supply AC Power Cord not included 0024 1179 11 Plastic End Cap 0106 5454 12 Filter Wadding 0007 1647 13 Power Supply 0304 1713 14 AC Power Supply Cord 3 Wire 4998 8986 Condensate Pump 15 Complete Assembly 0024 1180 16 Reservoir 0106 5453 17 Plast...

Страница 7: ...Flue Gas Sample Conditioning System 8 Bacharach Inc Instruction 0024 9415 Figure 3 Replacement Parts 11 20 20 12 Part of Item 10 1 21 9 6 7 8 5 2 Part of Item 10 13 14 18 23 17 22 16 20 19 15 ...

Страница 8: ...cting a Bacharach Service Center at the following locations United States Bacharach Inc 621 Hunt Valley Circle New Kensington PA 15068 Phone 724 334 5051 Fax 724 334 5723 Email help mybacharach com Canada Bacharach of Canada Inc 20 Amber St Unit 7 Markham Ontario L3R SP4 Canada Phone 905 470 8985 Fax 905 470 8963 Email bachcan idirect com ...

Страница 9: ...Flue Gas Sample Conditioning System 10 Bacharach Inc Instruction 0024 9415 ...

Страница 10: ...Bacharach Inc 11 Flue Gas Sample Conditioning System Headquarters 621 Hunt Valley Circle New Kensington PA 15068 Ph 724 334 5000 Fax 724 334 5001 Toll Free 800 736 4666 Website www mybacharach com E mail help mybacharach com ...

Отзывы: