Attribute
Description
Reserved
:
Displays the sensor temperature in °C.
Displays the sensor’s approximate rate of
temperature change per half minute interval (°C
change over 30 seconds).
Reserved
:
8.3. Resetting MGS-250 to Default Values
The gas detector may be reset to its default state, if needed, to aid in
troubleshooting. All settings, including alarm setpoint, gas adjustments,
selected gas curve, calibration data, Modbus address, etc. revert to
specific default values after a reset. The broadband sensor option (P/N
6401-0500) resets to gas group 1. Gas specific products (P/Ns 6401-
0501 through 6401-0515) are reset to the R134a gas curve.
IMPORTANT: Calibrations on either gas-specific or
broadband models are lost after a reset. This returns the gas
detector to an uncalibrated condition. See parameter P.-17
for information on how to recalibrate the gas detector.
Before performing this operation it is advisable to write down all the
parameter settings, so they can be re-programmed.