G75-DFC - Differential Filtration Controller 

| IOM

IOM

IOM

INDEX

INTRODUCTION

 

4

General

 ..............................................................................................................................................

4

Display:

 ..............................................................................................................................................

4

Technical Data

...............................................................................................................................

4

SAFETY INSTRUCTIONS

 

5

General

 ..............................................................................................................................................

5

Preparation to Installation

 .....................................................................................................

5

Installation

 .......................................................................................................................................

5

First Startup

 ...................................................................................................................................

5

Operation and Maintenance:

 ...............................................................................................

5

The G-75-DFC Main Components

 ......................................................................................

6

INSTALLATION

 

7

G75-DFC - Wires assignment

 ...............................................................................................

7

DP Switch Installation

 ..............................................................................................................

7

LV9000 - Wire Connectors

 

8

(Provided by Blazing Waterproof  

Small Wire Connector | LV9000)

 .......................................................................................

8

DryConn #22 to #12 AWG - Wire Connectors

 

8

(Provided by DryConn)

 ............................................................................................................

8

BATTERY INSTALLATION

 

9

Before installing the battery

 .................................................................................................

9

Replacing the battery:

 ..............................................................................................................

9

The User Interface

 

10

Monitoring the controller’s operation

 ............................................................................

10

The Auto mode

 .............................................................................................................................

10

The OFF mode

 ...............................................................................................................................

10

Switching operation modes

 .................................................................................................

10

The backwash cycles counter

 .............................................................................................

10

Starting a backwash cycle manually

 ..............................................................................

10

Programing the controller

 .....................................................................................................

11

Factory-Set Parameters:

 ..........................................................................................................

11

User Programable Parameters:

 ...........................................................................................

11

Setting the Interval Time between backwash cycles

 ...........................................

12

Setting the number of filters:

 ..............................................................................................

12

TROUBLESHOOTING

 

13

WARRANTY

 

14

Содержание G75-DFC

Страница 1: ...G75 DFC A U T O M A T I O N C O N T R O L Tackling climate change together Differential Filtration Controller Installation Operation Maintenance IOM...

Страница 2: ...part any part of this document or its content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this...

Страница 3: ...Waterproof Small Wire Connector LV9000 8 DryConn 22 to 12 AWG Wire Connectors 8 Provided by DryConn 8 BATTERY INSTALLATION 9 Before installing the battery 9 Replacing the battery 9 The User Interface...

Страница 4: ...replacing a Low Battery icon appears on screen Technical Data Controller Set Supplied with DFC controller suitable for DC only and one analog sensor Mechanical Operating temperature 10 C to 60 C Outdo...

Страница 5: ...vant standards and regulations Electrical wiring should be performed by an authorized electrician only using standardized and approved components and tools Locate the G75 DFC Filtration Controller whe...

Страница 6: ...ontroller The G 75 DFC Main Components Electric cable Pipe fitting Mounting screws x 2 Pipe fitting Controller D Upper digits UD Lower digits LD DP Pipe fitting Mounting screws x 2 Controller DFC disp...

Страница 7: ...e Connects to the black wire of solenoid number 3 filter valve 3 Black wire of the Differential Pressure switch DP Switch Installation Connect the controller s molded cable with the 3 wire connector t...

Страница 8: ...ed connection Do not reuse DryConn 22 to 12 AWG Wire Connectors Provide by DryConn 1 Strip 22 18 wires 1 2 12 7mm And 16 12 wires 3 8 9 5mm 2 Align any frayed strands or conductors 3 Pre twisting unne...

Страница 9: ...k the cover and secure the four screws The LCD display shows The actual differential pressure DIF The pressure set point SET The flushing cycles counter FC While in flushing a Faucet icon appeases on...

Страница 10: ...the controller is paused such as off season or when controlling the filters is not required In the OFF mode the lower line of the controller LD displays OFF In this mode the controller stops reading t...

Страница 11: ...samples shortens The maximal interval time between readings is 60 seconds while the minimal interval time between readings is 5 seconds The delay between filters during flushing Off time between valve...

Страница 12: ...the above process for filters number 2 and 3 2 Using the and the keys adjust the minutes If A is selected press SET to complete the setting 3 Press SET to continue 4 Using the and the keys adjust the...

Страница 13: ...y 1 Incorrect DP settings Low 1 Check if the DP is set too low 1 Set the DP to 0 5 bar 2 Sensor not zeroed 2 Disconnect the upstream and downstream tubes and check that the pressure indicated in the o...

Страница 14: ...yer shall deliver the product to one of Baccara s facilities and collect it from the same facility once repair is completed G75 DFC 22 04 21 Page 15 of 15 Warranty Baccara Geva ACS Ltd Baccara product...