Roof Hatch, Smoke Vent and Floor Door Safety Railings 

Installation, Operation & Maintenance 

              

                                                                                         Model(s): BSRA/BSRV/BSRT

 

 

 

 

 

Exit Options – Chain, 

figure 8 

This option is intended for roof hatch and floor door applications. 

1.

 

Remove set screws from top elbow or collar fitting of railing system. 

2.

 

Install provided eye bolts in set screw holes, 

figure 9

3.

 

Assemble chain and spring clips and install on eye bolts. 
 

Exit Option – No Exit, Two and Four-Sided Rails 

This option is intended for smoke vents and equipment roof hatches when there is no required exit. 

 

 

 

OPERATION 

Assure that all fasteners are tightened to the suggested torque. The gate should fully open and 
close with no interference. The roof hatch should operate without interfering with the safety 
railing. 

MAINTENANCE 

o

 

It is recommended that the springs in gate be lubricated once a year to preserve the spring, 
and that all fasteners meet the recommended torque setting. 

QUESTIONS? 

For more information on installation, repair or replacement, please visit 

www.BabcockDavis.com

 or call 888.412.3726. 

 

 

 

Figure 8 

 

Содержание BSRA

Страница 1: ...portation Storage o Inspect all shipments and materials for missing or damaged components and hardware o Railings may ship in multiple boxes depending on its size and exit configuration To help keep systems together the boxes will come banded together that form a full system o Material must be stored in a clean dry location Tools o Level o Marking Tool o Drill o 1 2 Drill Bit o Caulking o 3 16 All...

Страница 2: ... that the bracket is sitting square and level on the counterflash 4 Mark the mounting holes on each corner and drill 1 2 diameter holes Remove 3 8 16 nut and bolt 20 30 from the bracket halves 10 5 Fasten to the corner on counterflashing using 3 8 16 x 3 4 bolts 30 washers 40 and threaded nut plate 50 which is placed behind the counterflash for quick easy installation a If mounting holes were dril...

Страница 3: ... for example with corner brackets 2 Assemble top rail and center post Temporarily attach it to corner posts to verify location of center post bracket 3 Assure that the bracket is sitting square and level on the counter flashing 4 Mark the mounting holes on the counter flash and drill 1 2 diameter holes Remove 3 8 16 nut and bolt from bracket halves and top rail assembly 5 Fasten to the center of t...

Страница 4: ...ghten the set screws 5 Position the mid rail 21 center to center from the top rail 6 If necessary install end cap on single upright post Exit Option Self Closing Gate figure 6 This option is intended for roof hatch and floor door applications 1 Railing packages include a chain If installing a gate the chain is not used 2 Remove provided hardware pouch attached to the safety gate 3 Install safety g...

Страница 5: ...ion No Exit Two and Four Sided Rails This option is intended for smoke vents and equipment roof hatches when there is no required exit OPERATION Assure that all fasteners are tightened to the suggested torque The gate should fully open and close with no interference The roof hatch should operate without interfering with the safety railing MAINTENANCE o It is recommended that the springs in gate be...

Отзывы: