background image

12

© Baader Planetarium GmbH | 2019

13

Instruction manual: Baader Diamond Steeltrack

®

All BDS: adjusting the drawtube to align 
with the optical axis of your telescope 

Baader Diamond Steeltrack

®

 (BDS) focusers are unique in their ability to be fine-aligned (collimated), 

enabling critical users to achieve accurate alignment, or ‘squaring-on’ of the focuser to the optical 

axis. This is particularly useful for imagers who require the imaging plane to be accurately square 

to the optical axis in order to produce sharp stars out to all corners of their images. Critical users 

of SCT telescopes will also find this alignment capability useful, to give them the necessary degree 

of freedom to finally achieve accurate alignment of the focuser axis to the optical axis (alignment of 

the focuser axis to the center of the secondary mirror). 
Every BDS focuser is perfectly precision aligned at our factory to be square to its mounting base. 

Most users will find that this nominal alignment is sufficient to give very good performance with 

most commercially produced telescopes and that adjustment of the focuser alignment is not nee-

ded or desired. This is particularly the case for visual observers, where precise squaring-on of an 
eyepiece is not needed nor even detectable.

Warning, please note:

• 

The following adjustment procedure is provided for those users who require an accurate alignment 

(‘squaring-on’) of the focuser to the optical axis. We do not recommend it for most visual uses.

• 

Before attempting any adjustment, we recommend that you first read through these instructions 

completely in order to familiarize yourself with the process.

• 

Adjusting a focuser can be very tricky. We recommend always making only small adjustments / 

turning screws by a small amount in order to be able to gradually home in on the perfect setting. 

Too large adjustments will give rise to a result that is uncontrollable.

• 

Right at the beginning of the procedure, you should first take note of the force required to pull 

out the focuser tube against the existing contact pressure. This force should not be substantially 

exceeded to avoid damaging the mechanism.

• 

During the first adjustment procedure, no heavy accessories should be attached – the focuser 

tube is loose and could slip out. Once you are familiar with the procedure and you know how 

the focuser behaves you can dare to leave your camera on the focuser while adjusting. Please 

note that Baader Planetarium will not be held responsible for damages to your equipment due 

to slipping of the drawtube. 

• 

All BDS focusers have been designed so strong to carry heaviest loads without danger to any 

of the components. We are convinced that any damage done to bearings or drive mechanism 

represents a clear sign of improper handling. In general screws should never be tightened too 

firmly as mechanical parts, such as bearings, could be subjected to high loads and thereby 

destroyed. Such treatment may void the warranty and result in costly repairs.

Please read the following thoroughly and only proceed with the alignment procedure if you 

feel well informed about what you are doing.

Tools Required:

1.  Metric Hex Keys (2mm, 2.5mm, 4mm) 
2.  Collimation Tool: We recommend the use of a collimation tool to monitor changes in focuser 

adjustment and to attain accurate alignment of the focuser axis to the optical axis. A laser colli-

mator such as the Baader Mark III LaserColli

TM

 

(#2450343) 

is ideal for this purpose (RT/NT only).

Adjustment procedure:

Screws marked No.8 are holding the bearing block in place which fastens all four roller-bearings. 

These two screws are the pivot point for the bearing block. Screws no. 6-9 are the bearing adjust-

ment screws we are aiming at for this instruction. The focuser is set to a certain pressure. Tightening 

down the adjustment screws will increase the pressure even more. So before you tighten something 

you always must at first release pressure at the other side (

means: when you for instance tighten 

screws 5+7 or 4+6 at the same time, you must first release the screw 8 at the same side

).

Up and Down

A:

 Shifting the drawtube up on the CCD side and down on 

the telescope side:

•  Loosen screws 4 and 5 by ½ turn
•  Tighten screws 6 and 7 by ½ turn

B:

 Shifting the drawtube down on the CCD side and up on 

the telescope side.

•  Loosen screws 6 and 7 by ½ turn
•  Tighten screws 4 and 5 by ½ turn

Sideways 

(This is not very handy to do as the up and down positi-

on will always simultaneously change slightly. Only VERY 

slight changes should be made) 

C:

 Shifting the drawtube sideways to the left

•  Loosen screws 4 and 7 by ¼ turn
•  Tighten screws 5 and 6 by ¼ turn 

D:

 Shifting the drawtube sideways to the right

•  Loosen screws 5 and 6 by ¼ turn
•  Tighten screws 4 and 7 by ¼ turn 

More adjustment typically is not necessary. We recommend not to change the factory centering. 

Nevertheless it is possible (as shown below). 

If you feel comfortable with what you are doing, you 

can change the entire center position of the drawtube which we had set as factory setting. This may 

only become necessary if your lens is not perfectly centered with your mechanics to a large degree. 

Centering can be checked by putting a star in the center of your chip and rotating the focuser. If the 

star circles on the chip your focuser is not fully centered to the lens. You may be able to tilt the lens 

with the tip tilt screws. However, many scopes do not offer this possibility. Therefore the BDS offers to 

displace the entire drawtube to a very small degree, for finding the new optical/mechanical centerline. 

You should make small iterative adjustments rather than doing one BIG change and ruin the hole adjust-

ment beyond return. Carefully watch out to not have the drawtube scratch against  the outer housing.

Lifting/Lowering drawtube in parallel to the  

focuser housing

E:

 Lifting the whole drawtube up 

•  Loosen screws 4-7 as well as 3.2 by ½ turn
•  Tighten screws 3.1 by ½ turn as well as screws 2 and 1 

by ¼ turn, then fasten screws 8 and 3.2 hand tight 

Then check if every screw except 1 is tight and fasten it 

hand tight if necessary. Check the lifting force and adjust 

screw 2 until the payload does not slip if in vertical position.

 

F:

 Lowering the whole drawtube down

•  Loosen screws 8, 3.1 and 3.2 by ½ turn as well as 

screws 2 and 1 by ¼ turn

•  Tighten screws 4-7 by ½ turn, then fasten all other 

screws except 1 hand tight 

Then check if every screw except 1 is tight and fasten it 

hand tight if necessary. Check the lifting force and adjust 

screw 2 until the payload does not slip if in vertical position.

In case the optimum adjustment has not yet been achieved, you should repeat the procedure. After 

a short time, you will develop a feel for the interaction of the various adjusting screws. In each case, 

make sure not to continue increasing the pressure in the same direction without relieving it in the 

opposite direction accordingly, in order to avoid damage to the mechanics.

A

B

B

A

4

6

5

7

C

D

D

C

8

E

E

F

F

3.1

3.2

2

1

4

6

8

5

7

Содержание 2957210

Страница 1: ...ader Diamond Steeltrack BDS focusers BAADER PLANETARIUM ZurSternwarte4 D 82291Mammendorf Tel 49 0 8145 8089 0 Fax 49 0 8145 8089 105 www baader planetarium com kontakt baader planetarium de www celest...

Страница 2: ...cuser height backfocus and rigidity requirements Zero shift locking knob to precisely stop any movement without affecting optical axis adjustment Focusing Drawtube Each bearing individually adjustable...

Страница 3: ...Integrated 2 standard clamp 4 6 x M2 5 headless setscrews Loosen with included 1 3 mm Allen wrench to detach the integrated 2 stan dard clamp and to mount the optional 2 BDS S58 Clicklock Clamp 295625...

Страница 4: ...s To access remove 2 3 3 adapter by loosening 6 x M5 screws 4 Integrated 2 standard clamp 5 6 x M2 5 headless setscrews Loosen with included 1 3 mm Allen wrench to detach the integrated 2 standard cla...

Страница 5: ...ard clamp and to mount the optional 2 BDS S58 Clicklock Clamp 2956258 respectively T 2 M48 or M68 ad apters 2957202 04 06 8 Recessed area allows the use of very short 1 reducers e g Baader Pushfix ada...

Страница 6: ...ic use You can untighten it for visual use to make the focuser even more smooth running 3 Screws for factory setting of the optical axis You should not change these settings For further information se...

Страница 7: ...he Baader Mark III LaserColliTM 2450343 is ideal for this purpose RT NT only Adjustment procedure Screws marked No 8 are holding the bearing block in place which fastens all four roller bearings These...

Страница 8: ...two of the 5 x M5 screws see also 3 on page 4 These screws serve only to cover the M5 threads that have been drilled in the BDS RT housing to allow attachment of further accessories All BDS optional...

Страница 9: ...r years Every shop that features a window display facing the sun experiences this ef fect Leather shoes textiles etc fade within a short period of time anodized metallic surfaces suffer the same effec...

Отзывы: