background image

5.1 Instruction for touch panel 

5. Functions

1

4

3

2

5

5.2 IDT 

(Intensity Duty-Cycle Timer)

 settings

• 

        Intensity Setting

Depending on the strength, thickness, and shape of the material, operator 
can set the light intensity from Level 1(lowest) to Level 16(strongest). Intensity 
range: 7018 –112295 mW/cm

2

  when LED current at 43.8-700mA.

Suggestion: When curing flat and/or thin material, lower the intensity level 
with longer timer to optimize the overall strength of the material.

           Adjust the light intensity from Level 1 to Level 16.
           Adjust the duty cycle (See chapter 5.2) from Level 1 to Level 10
          (consistent brightness)
           Adjust the working time between 5 seconds - 30 minutes.
    Display: Indicate numerical value and remaining seconds.
    + : Increase the level of intensity, duty cycle and working time. Hold and 
           press the button to fast-forward.
    - : Decrease the level of intensity, duty cycle and working time. Hold and 
           press the button to rewind. 
            : Start and stop curing

1
1

1
2
3

4

5

8

Содержание Cure XL

Страница 1: ...Instructions for Use...

Страница 2: ......

Страница 3: ...ncerely hope that it will give you many years of trouble free use Please read and understand all the instructions before using this equipment Save these instructions for use for your reference The ins...

Страница 4: ...ons for use 6 4 Package And Part Name 7 4 1 Main unit part name 7 4 2 Table of contents 7 5 Functions 8 5 1 Instruction for touch panel 8 5 2 IDT Intensity Duty Cycle Timer setting 8 5 3 Basic operati...

Страница 5: ...t in minor moderate injury or damage of property Hot Surface Danger Electricity 1 2 On the product packaging Serial number Catalogue number Manufacturer Date of manufacture Atmospheric pressure for st...

Страница 6: ...r chemicals or a location where gas is released Do not keep the product at a sloping location Do not shake or impact the product Use only AC100 240 V power supply voltage Using the wrong voltage input...

Страница 7: ...tch off the power switch immediately Pull out the plug and contact the distributor If water leaks inside the product switch off the power switch immediately Pull out the plug and contact the distribut...

Страница 8: ...oduct When moving the product please switch off the power switch and pull out the plug When pulling out the plug do not pull out the power cord When checking wiping or replacing fuses always turn off...

Страница 9: ...nd high power LED with constant current circuit avoid the cost and hastle of replacing UV fluorescent light tube Multiple functions Users can set up the curing details easily to gain process efficienc...

Страница 10: ...nents Description B9 Model Cure XL Power cord Instructions for use Quantity 1 1 1 1 Operation Panel 2 Handle 3 Door 4 Power Button 1 4 3 2 5 Cooling fan 6 Power Switch 7 Fuse 8 Outlet 6 5 7 USE ONLY W...

Страница 11: ...ower the intensity level with longer timer to optimize the overall strength of the material Adjust the light intensity from Level 1 to Level 16 Adjust the duty cycle See chapter 5 2 from Level 1 to Le...

Страница 12: ...Depending on the shrinking rate of the material operator can set the duty cycle from level1 10 to level 10 100 Suggestion When curing small and or thin material lower the duty cycle level to reduce t...

Страница 13: ...pausing curing Press to increase or press to decrease curing time After adjusting the curing time press to restart 5 3 3 Reset IDT when pausing curing Press the buttons to reset IDT setting After res...

Страница 14: ...placement After replacement if there s still a problem with the panel indicator please contact customer service for repair USE ONLY WITH A 250V FUSE USE ONLY WITH A 250V FUSE Trouble Possible Cause Me...

Страница 15: ...ce switch off the power swtich and pull out the plug 7 1 Cleaning inner chamber 1 When the inner chamber gets dirty clean it with soft cloth with alcohol or cleaner 2 If resin adheres to any part of t...

Страница 16: ...nm Curing time 5 seconds 30 minutes Dimensions L200 x W220 x H160 mm max Weight 3 Kg Operating environment Indoor use only Ambient temperature Relative humidity Atmospheric pressure Storage and transp...

Страница 17: ...llowing are expressly excluded from the warranty 1 Damage and or failure of the equipment caused by falling and or jolting during transportation after purchase and or during the normal use 2 Damage an...

Страница 18: ......

Отзывы: