10
SLD5k
Strapped control panel setting steps
PROTECT
POWER
REMOTE
BOOST
FREQ.
LPF
PHASE
SUBSONIC
GAIN
BASS
SLAVE
OUTPUT
MASTER
INPUT
SLAVE
INPUT
R
L
0.2V
6V
10Hz
50Hz
0dB
9dB
30Hz
90Hz 35Hz
250Hz
0
180
MASTER
SPEAKER
PROTECT
POWER
REMOTE
BOOST
FREQ.
LPF
PHASE
SUBSONIC
GAIN
BASS
SLAVE
OUTPUT
MASTER
INPUT
SLAVE
INPUT
R
L
0.2V
6V
10Hz
50Hz
0dB
9dB
30Hz
90Hz 35Hz
250Hz
0
180
MASTER
SPEAKER
*
Set slave as slave, button pushed in.
*
Leave Master unpressed
HEAD UNIT
To link the master and slave amplifier RCA connection follow the steps below.
Keep in mind amplifiers needs to be switched off, linking the amplifiers when switched on may cause harm and can void your warranty!
Step 1.
Connect RCA from Head Unit / output source into
master
amplifier RCA input.
If only one output is available, then use a Y-split to connect both L & R.
Step 2.
Locate the Master / Slave switch on the right side of the control panel on the
Master
amplifier.
Set the switch to
Master
position (unpressed).
step 3.
Connect a single RCA from the
RCA OUT
on the
master
amplifier.
Step 4.
Locate the Master / Slave switch on the right side of the control panel on the
Slave
amplifier.
Set the switch to
Slave
position (pressed).
Step 5.
Connect the single RCA cable from the
Master
amplifier’s
Rca out
to the
slave
amplifier’s single
RCA IN
.