background image

2

1. Introduction

Congratulations for having purchased a B.Well Piston Compressor Nebulizer 

Model WN-115 K. Thanks for your support.

B.Well warrants that this device has been produced using high quality 

materials and it complies with the safety rules in force both domestically and 

internationally.

Please read the instructions carefully before using the device and proceed 

accordingly.

2. Recommendations

Read the manual carefully before using the device and keep it in case you need 

further information in the future.

This product was intended for aerosoltherapy only. Any other use will be 

considered wrong and consequently dangerous; the manufacturer will not be 

held responsible for damages caused by misuse or if the device has been used in 

electric fittings which do not comply with the safety rules in force.

Please take into account the following relevant points:

•The device is not protected from liquid penetration.
•The device should not be touched with wet or soaking hands.
•Keep the device in a safe place.
•Do not use the device in the presence of inflammable anesthetic substances 
in contact with air, oxygen or nitrogen protoxide.
•Unplug the device before doing the cleaning or the maintenance operations. 
Unplug the unit when it is not being used.
•Do not untwist the jet nebulizer during operation.
•Do not leave solution into the jet nebulizer when it is not in use.
•Do not pour more than 10 ml of solution into the jet nebulizer.
•Place the device on an even, safe surface.
•Do not dip the device in water.
•Use the unit intermittently. Maximum operating period: 30 minutes.
Rest period: 30 minutes.
•The accessories should not be shared by different patients to avoid infections 

Содержание WN-115K

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ...tion 2 Recommendations 3 Features 4 Unit Assembly 5 Operating Instructions 6 Filter change 7 Cleaning and Maintenance 8 Spare parts provided 9 Technical Specifications 10 Service Parts List 11 Trouble...

Страница 5: ...sed in electric fittings which do not comply with the safety rules in force Please take into account the following relevant points The device is not protected from liquid penetration The device should...

Страница 6: ...his device can only be repaired by service agents authorized by B Well NOTE This device carries a thermal limiter which will shut off the unit to avoid overheat 3 Features Pediatric mask Jet nebulizer...

Страница 7: ...4 IMPORTANT Do not pour more than 10 ml 4 Unit Assembly...

Страница 8: ...emove filter cap by grasping it firmly and pulling out the unit 3 Change the dirty filter of the cap with small pointed object 4 Insert a clean filter Extra filters are available 5 Push the filter cap...

Страница 9: ...the out part of the unit The jet nebulizer and the devices must NOT be boiled The jet nebulizer has to be replaced if it is stuck by medication or other substances Under no circumstances will the unit...

Страница 10: ...ow range 6 8 5 l min Approximate maximum pressure 225 56 kPa 32 73 PSI 2 3 kg cm2 Flow maximum 10 l min Weight 1 732 kg Unit dimensions 240 x 140 x 124 mm 9 4 x 5 5 x 4 9 Operation Humidity and Temper...

Страница 11: ...equiring reposition please ask for the parts mentioning the code number Illustration Description Code number Jet nebulizer NA L115K PVC tubing NA 115K Pediatric mask NA M 115K Adult mask NA M115K Mout...

Страница 12: ...Verify if there is electrical energy The aerosol doesn t come out from the jet nebulizer Aerosol output reduced low 1 Not enough medication in jet nebulizer 2 Too much medication 3 PVC tubing disconne...

Страница 13: ...Cambridge Road Enfield Middlesex EN1 3PN United Kingdom 14 Warranty B Well warrants to the original retail purchaser that this product is free from defects in material and workmanship for a period of...

Страница 14: ...11...

Страница 15: ......

Страница 16: ...B Well WN 115 K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 15 16 17 17 18 19 20 20 22 22 23...

Страница 17: ...14 1 WN 115 K B Well B Well 2 10...

Страница 18: ...15 30 30 B Well 3...

Страница 19: ...16 4 10...

Страница 20: ...17 5 1 2 10 3 D 4 E 5 6 I 7 8 9 6 1 2 3 4...

Страница 21: ...18 7 30 30 3 1 B Well...

Страница 22: ...19 8 1 2 1 2 1 2 3 4 5 1 10 2 3 4 5...

Страница 23: ...20 9 220 50 0 6 10 5 0 33 6 8 5 2 3 2 1 732 240 140 124 5 40 30 95 10 40 10 95 500 1060 10 1 1 1 1 1 3 1 1 NA L115K...

Страница 24: ...21 1 5 1 NA 115K 1 NA N115K 1 NA M115K 1 NA M 115K 3 NA F115K 1...

Страница 25: ...22 11 II 12 2006 91 30 01 06 EN 60601 1 EN 60601 1 2 EN 55011 B Well Limited 758 EN1 3PN...

Страница 26: ...13 B Well 3 23...