Instructions for use

TH-134  •  TH-135

En

6

4.   NOTICE FOR SAFETY OPERATION

To ensure safety, please do follow all rules below:

1. Before using

  •  Use this appliance in the correct manners outlined in this manual.
  •  This appliance had to operate under nominal temperature (10ºC ~ 40ºC), outside the 

nominal temperature range was not suitable to operate the product.

  •  Before Using, please proceed with cleaning procedure described in the cleaning and 

maintenance procedure.

  •  The medicine treatment should according to doctor’s advice.
  •  If the product operates improperly, please discontinue use it and send it for repairing 

immediately or consult your dealer.

  •  If the medical cup is not functioning very well (such as very weak spray volume etc.), 

before using, please replace it.

  •  When this appliance has not been used for a while, if any part (such as medical cup, 

mouth piece or mask) seems dirty, please proceed with cleaning procedure described 
in the cleaning and maintenance procedure.

  •  Do not add medicine over the indicated line marked on medical cup (8c.c marking).
  •  Do not disassemble or make any modifi cation on this appliance.

2. Under using

  •  Children or disable patients should be assisted by adults or medical personnel when 

using this appliance.

  •  Do not use this appliance under a high humid environment (>85% RH)
  •  Do not use this product if the medical cup without any medicine.
  •  Keep the appliance in fl at position and steady during operation to avoid spillage.
  •  Do not open the cover of medical cup during operation.
  •  Keep eyes away from the mist output.
  •  Treatment period please follow the doctor’s advice.

Содержание TH-134

Страница 1: ...MESH NEBULIZER MODEL TH 134 MODEL TH 135 I n s t r u c t i o n s f o r u s e M E S H N E B U L I Z E R M O D E L T H 1 3 4 T H 1 3 5 READTHIS INSTRUCTION MANUAL CAREFULLY BEFORE USE...

Страница 2: ...4 2 Intended purpose Page 4 3 Precautions Page 4 4 Notice for safety operation Page 6 5 Name of component Page 8 6 How to use Page 9 7 Clean and maintenance notice Page 10 8 Disinfection Page 11 9 Tro...

Страница 3: ...nder the guidance of quali ed medical experts Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s o ce in a room of general household and in open ai...

Страница 4: ...e raised to 40 C the product shelf temperature will raise up to 50 C 15 Do not use nebulizer on top of or close to other electronic device 16 Do not drop the nebulizer Do not apply strong shocks to th...

Страница 5: ...such as very weak spray volume etc before using please replace it When this appliance has not been used for a while if any part such as medical cup mouth piece or mask seems dirty please proceed with...

Страница 6: ...ny irregularity or discomfort is observed please discon tinue use this appliance This product has built in a 20 minute shuto timer If it cannot be shuto automati cally discontinue using and consult yo...

Страница 7: ...rn red and ash three times before turn o automatically However the no medication detector has the possibility not function if that mesh blocked by medication 3 Medical Cup Contain the medicine Suggest...

Страница 8: ...ailure to do so could result in damage due to battery leakage 2 Discard the waste batteries according to local law 3 Open the medical cup cover and pour the medicine into the medical cup and close the...

Страница 9: ...ur in some hot water and close the cover completely Press the power button and operate 1 2 minutes to discard all remaining medicine completely Ensure medicine be cleaned completely after each using o...

Страница 10: ...indicator light is on the battery power is too low Please replace the battery immediately 2 Discard the waste batteries according to local law 3 Check the battery is installed correctly Open battery c...

Страница 11: ...ncorrect functioning of the nebulizer and can generate unsafe situations In order to prevent such unsafe situations your nebulizer is designed and tested according to EN60601 1 2 standards These stand...

Страница 12: ...battery indication 2 0V 2 2V orange light Low battery indication 2 0V red light Operation environment 10 40 C 30 80 RH Storage Transportationenvironment 20 70 C 85 RH Nebulization rate 0 2mL min 1 0mL...

Страница 13: ...12 SYMBOL INFORMATION symbol referent Read instructions before use Manufacturer s Name Article number Serial number Class II Equipment Type BF equipment Disposal for separate collection CE mark Prote...

Страница 14: ...B Well Swiss AG Bahnhofstrasse 24 CH 9443Widnau Switzerland ISO9001 ISO13485 Certi ed This device complies with European Council Directive 93 42 EEC on Medical Devices...

Страница 15: ...B Well Swiss AG Bahnhofstrasse 24 CH 9443Widnau Switzerland IM_TH 134_TH 135_ISO_2616...

Отзывы: