Automatic brightness control of the light
signalling device
In the standard version, the controller has a lighting sensor included, which is placed on the
LED panel. The device, in response to the ambient brightness, adjusts the light signalling device
brightness.
Initial start-up
Step 1: Make sure that all cables are properly connected,
Step 2: Make sure that all components have been installed in correct orientation,
Step 3 Connect the device to the mains power supply,
Step 4 The properly connected system will display the symbols "-" in the light fields, followed by
the hard space symbol ( _ ) in the bottom field . It means that the device is working according to
the default protocol. In 7 seconds, the signalling device will go into the default display state.
Changing Ethernet Settings
Wagset Software can be used to change the IP address. The TL-280 does not support a web
application like the BT-480.
WagSet 2:
WagSet 2 Software Download
Open Wagset, click “Create own Protocol”, Select File, then “display network settings”
Change IP address under “New Display Settings”, then click Send.