 6. Care and Maintenance 

 

Regular cleaning of emitters / tubes and reflector panel should be done by using a piece of soft cloth 
or cotton with solvent. Do not start the emitter / tube until the solvent has evaporated, otherwise it 
may lead to a fire / explosion. 

 

 

For replacement emitters / tubes, contact your distributor or the B-TEC Systems service center.

 

 

6.1 Replacement of Emitter Lamp Tube 

1.

 

Disconnect both the electric and air supply from the unit. 

2.

 

Remove the screws on the side and back panels of the unit and remove the panels.  

3.

 

Remove the screws of the protective grill in front of the emitter and take out the protective grill. 

4.

 

Loosen the two leads of the emitter /tube and remove it. 

5.

 

Fit the new emitter / tube and connect the leads after checking you have the correct part. 

6.

 

Use a piece of soft cloth or cotton to clean the reflector panel and the emitter / tube with solvent.  

7.

 

Refit the protective grill.  

8.

 

Refit the panels. 
 

 

 

 

 

 

 

 

 

         

 

Important: Wait 5 minutes before starting the unit to ensure that any solvent or solvent has evaporated 

 

 

 

Before conducting care and maintenance, be sure that the unit is disconnected from 
the electricity and air supply. Also ensure that the unit has cooled down.

 

Содержание ST-01

Страница 1: ...Operating Manual for Paint Sample Dryer ST 01 Paint Sample Dryer ST 01 ...

Страница 2: ...ents for pneumatic systems DIN EN ISO 4414 Special national norms are applied Safety and health signs at workplace BGV A8 Technical Parameters Rated voltage 120 V Rated frequency 60 Hz Rated power input 350 W Protection class I Degree of protection IPX0 Tested according to EN 60335 1 A2 2006 EN60335 2 30 A2 2007 EN50366 A1 2006 This EC Attestation of Conformity is issued on a voluntary basis accor...

Страница 3: ... the Symbols 1 2 Technical Description of the Machine 2 2 1 Technical Parameters 2 3 Safety Regulations 3 3 1 Safety and Advisory Notes 3 4 Installation 4 5 Operating Instructions 5 6 Care and Maintenance 6 6 1 Replacement of Emitter Lamp Tube 6 7 Wiring Diagram 7 ...

Страница 4: ... reference B TEC Systems devices and machines are only to be used for the purpose explicitly described below Any other use is in contrast with the regulations The manufacturer cannot be held liable for damages resulting from such non authorized use The intended use of this equipment is the drying of paint samples including waterborne coatings utilizing infrared and air movement Improper use can en...

Страница 5: ...el The compressed air and the infrared lamp can be used together or separately 2 1 Technical Parameters Model ST 01 Operating pressure compressed air connection 3 5 bar Rated voltage 120 V Rated frequency 60 Hz Power of the emitter 300 W Timing range of the timer 30 min Weight 6 1 kg Size W x H x D 16 x 12 x 8 inches Netzkabel Lufteingang Einschaltung Luft Luftmengeneinstellung Zeitschaltuhr Tempe...

Страница 6: ...m or any volatile area Ensure that all necessary protection is worn gloves eye protection airway protection whole body protection Hands have to be washed thoroughly before eating or drinking Do not use this equipment when it is wet or damp Water coming into the unit may lead to electric shock or damage to the equipment This equipment is not for outdoor use Do not cover the air vents as overheating...

Страница 7: ...e machine on a suitable sturdy bench table Compressed Air Connection One compressed air connection has to be provided by the plant depending on the machine Operating pressure max 5 bar 72 5 psi Operating pressure min 3 bar 43 5 psi A pressure regulating valve has to be used if the compressed air connections do not have the required operating pressures Use only dry and oil free air After proper ins...

Страница 8: ... dried using both infrared and air When the drying cycle is completed the unit will stop automatically and a bell ping will sound For top coat Clear or single stage 1 Turn the temperature control to high 2 Set the timer for 3 minutes and the curing cycle will start The sample is now being cured using only infrared When the drying cycle is completed the unit will stop automatically and a bell ping ...

Страница 9: ...els of the unit and remove the panels 3 Remove the screws of the protective grill in front of the emitter and take out the protective grill 4 Loosen the two leads of the emitter tube and remove it 5 Fit the new emitter tube and connect the leads after checking you have the correct part 6 Use a piece of soft cloth or cotton to clean the reflector panel and the emitter tube with solvent 7 Refit the ...

Страница 10: ... Tec Systems reserve the right to make technical changes without notice B TEC USA LLC 480 621 5304 www bteccleaners com IR Temperature adjustment SW1 0 30 Min TIMER 300W L E N 230V AIR IN OUT YV IN OUT Air switch Air knob 120V ...

Отзывы: