background image

 

IMPORTANT WARNINGS 

 

 

THIS  APPLIANCE  SHALL  ONLY  BE  INSTALLED/SERVICED  BY 
AN AUTHORISED INSTALLER. 

THIS  APPLIANCE  MUST  BE  INSTALLED  IN  ACCORDANCE 
WITH THE SPECIFIED INSTRUCTIONS AND SPECIFICATIONS. 

IMPROPER 

INSTALLATION 

OR 

OPERATION 

OF 

THIS 

APPLIANCE MAY RESULT IN PRODUCT FAILURE WHICH MAY 
LEAD  TO  PROPERTY  DAMAGE,  PERSONAL  INJURY  OR 
DEATH. 

CAUTION  MUST  BE  TAKEN  WHEN  OPERATING  THIS 
APPLIANCE  TO  MINIMISE  RISK  OF  FIRE.  THE  APPLIANCE 
MUST NOT BE LEFTON UNATTENDED. 

REGULAR  INSPECTIONS  BY  AN  AUTHORISED  SERVICE  PERSON  ARE  STRONGLY  RECOMMENDED 
TO ENSURE PROPER AND SAFE FUNCTIONING OF THIS APPLIANCE. 

AFTER  ANY  SERVICING  OR  ADJUSTING  OF  GAS  CONNECTED  COMPONENTRY,  GAS  LEAK  TEST 
MUST BE CARRIED OUT TO ENSURE THERE ARE NO GAS LEAKING HAZARDS. 

NEVER  STORE  ANY  FLAMEABLE  LIQUIDS/VAPOURS  IN  VACINITY  OF  THIS  APPLIANCE.  NEVER 
SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. 

ENSURE  ANY  TRANSIENT  PROTECTION  IS  REMOVED  BEFORE  INSTALLING  THE  APPLIANCE 
ENSURING ANY POSSIBLE DAMAGE TO THE APPLIANCE OR COMPONENTS/ PARTS THAT MAY HAVE 
BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER. 

THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT. ENSURE APPLIANCE 
IS INSTALLED IN A STABLE POSITION. 

FAILURE TO FOLLOW THE INFORMATION PROVIDED IN THIS BOOKLET WILL VOID THE B&S 

WARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY TO PERSONNEL. 

 

Table 1: Nominal Terminal Input Rates & Injector Sizes 

Burner Type 

Gas Type 

Injector Size 

(mm) 

MJ/h per Burner 

Test Point 

Pressure 

Duck Bill Burner 

(DB)

 

Natural Gas 

1.25 mm (x18) 

120 

1.00 kPa 

Propane Gas 

0.70 mm (x18) 

126 

2.60 kPa 

Chimney Burner 

(CB) 

Natural Gas 

0.95 mm (x24) 

115 

1.00 kPa 

Propane Gas 

0.55 mm (x24) 

120 

2.60 kPa 

 

Table 2: Standard Model General Information 

 

 

UFW/WSP-1 
UFW/WSP-2 
UFW/WSP-3 

      Weight                    Overall Height        Overall Depth*        Overall Width*           

(kg) 

 (mm) 

  (mm) 

  (mm) 

 

 

100 

1,300 

840 

650 

 

200 

1,300 

840 

1,300 

 

300 

1,300 

840 

1,950 

 

 

Overall Dimensions 

– Custom made appliances

 

Height over splashback   

: 570mm - 1,300mm + adjustable legs.  

Width   

 

 

: 1,950mm minimum with 3 stock pots.  

Depth   

 

 

: 800mm minimum. 

 
 
 
 
 
 

Содержание UFW Series

Страница 1: ...54 Fax 61 3 94694504 Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the manufacturer Owing to continual product development and improvements to its products B S Commercial Kitchens Pty Ltd reserves t...

Страница 2: ...ation Instructions 6 Regulations 6 Data Label 6 Ventilation 6 Combustible Surfaces 6 Gas Connection 7 Pressure Test Point 7 Water Connection 7 Before Leaving Commissioning 7 Operating Instructions 8 IMPORTANT WARNING 8 IMPORTANT WARNING 8 Lighting Instructions 8 Shutdown Procedure 9 Deck Cooking Water Spray Where Fitted Water Cooled Models 9 Telescopic Laundry Arm Manual Control Water Cooled Model...

Страница 3: ...1 Gaining Access to Gas and or Water System 11 Removal of Burner for Service 11 Pilot and Flame Safeguard 11 Adjustments 12 Servicing WokSpout Where Fitted 12 Servicing Knee Valve Where Fitted 12 Gas Type Conversion 12 Table 4 Spare Parts List 13 Table 5 Troubleshooting 14 ...

Страница 4: ...allation of the appliance please contact your B S dealer immediately In most instances a phone call could answer your question Manufactured By Certificate Holder Model Number s Approval Number Gas Types B S Commercial Kitchen s Pty Ltd 57 Plateau Road Reservoir Victoria 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscommercialkitchens com How to read model numbers UFW W D SP 1 2 3 CB LS ...

Страница 5: ...IS REMOVED BEFORE INSTALLING THE APPLIANCE ENSURING ANY POSSIBLE DAMAGE TO THE APPLIANCE OR COMPONENTS PARTS THAT MAY HAVE BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION FAILURE TO FOLLOW THE INFORMATION PROVIDED IN THIS BOOKLET WILL VOID THE B S WARRANTY AND M...

Страница 6: ...gas supply is correct for the appliance being installed and that adequate supply pressure and volume is available refer to appliance data plate for Mj hr consumption injector sizes of main burners pilots etc Ventilation It is strongly recommended that the appliance is installed under an extraction hood Ventilation must be in accordance with AS5601 Gas Installations In general the appliance should ...

Страница 7: ...2 60 kPa LPG with the burners operating at maximum Water Connection The water connection is 15mm copper and is situated at the rear of the appliance below the main body frame The number of water inlets varies to client s particular needs Water isolation valves are fitted to all water inlets Ensure water is flushed through before final connection Water waste outlet is located on the left hand side ...

Страница 8: ...gas please note that as some gas types are heavier than air we recommended the operator to also smell the floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operate any electrical switch or phone in your building Call local gas supplier immediately and follow their instructions IMPORTANT WARNING ALWAYS ENSURE DECK COOLING IS ACTIVATED WHILST MAIN BURNER I...

Страница 9: ... FROM TELESCOPIC LAUNDRY ARM WHILST POSITIONED OVER THE STOCK POT SUPPORT RING WITH NO POT PAN POSITIONED ON IT ALWAYS MOVE TELESCOPIC LAUNDRY ARM PARALLEL TO THE SPLASHBACK OG THE APPLIANCE WHENNOT IN USE DIRECT FLAME CONTACT WITH LAUNDRY ARM MAY DAMAGE OPERATION OF LAUNDRY ARM SPOUT Waterset Automatic Laundry Arm WokSpout Where Fitted The WokSpout automatically shuts off the water flow when it I...

Страница 10: ...ils dust and any other materials Ensure the primary water drain located in gutter is cleared of any food stuffs during operation of the appliance and on completion of use of the appliance The spillage trays located under the main body of the appliance should be removed by pulling out and any carbonised foodstuffs and oils should be removed using a clean damp cloth soaked in a mild detergent Fortni...

Страница 11: ...e b Gently remove dome handle by gently pulling forward c Unscrew flange by turning anti clockwise d Unscrew water spindle by turning anti clockwise ensure spindle washer is removed 6 Remove screws located on bottom corners of front panel Ensure any screws located on the inside of the gutter panel are also removed 7 Gently pull front panel outwards from the bottom and lift front panel upwards 8 RE...

Страница 12: ... service be carried out every two years Please contact manufacturer for service kit Servicing Knee Valve Where Fitted The knee valve incorporates a cartridge design for ease of service 1 Follow procedure described under GAINING ACCESS TO GAS AND OR WATER SYSTEM 2 To gain access to knee valve cartridge undo knee valve where the deflector meets the cartridge area 3 REASSAMBLE IN REVERSE ORDER Gas Ty...

Страница 13: ...rmocouple Front row burner boiling top section flame failure device 665NG Oara Regulator Natural Gas 665LP Oara Regulator Propane Gas 020 Telescopic Laundry Arm 503 Pilot Shield 504A 12 Flexi Tube From Flame Failure Device to Pilot Gas Cock 504B 18 Flexi Tube From Pilot Gas Cock to Light Burner W001 Knee Valve W004 Cartridge W002 Waterset Laundry Arm W003 Lever Handle W005 Retaining Disk and Handl...

Страница 14: ...ing Faulty thermocouple Faulty flame failure control valve Contact manufacturer Contact manufacturer Telescopic laundry arm constantly running on water deck cooled stock pot table Warn tap washer Change washers in tap assembly Contact manufacturer or authorised service agent Wokspout constantly running water when in OFF position Faulty O ring in Wokspout Changing of O ring as per service kit and i...

Отзывы: