B.O.L.T VA 01 Скачать руководство пользователя страница 22

B.O.L.T User Manual 

 

Model No: VA 01 

  

22 

© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd. 

 

Readings are not received in 
mail 

Mail Entries in Near & 
Dear section 

Click Near & Dear option in 
settings panel and verify 
the mail IDs and retry 

 
 
 

16.

 

Explanation of Indicators/Symbols 

Indicators/Symbols 

Function/Description 

 

 

 

The indicator displays full battery power of the gadget in the 
mobile device. 

 

   

 

 

The indicator displays low battery power of the gadget in the 
mobile device. 

 

SYS 

 

Systolic blood pressure in mmHg. 

 

DIA 

 

 
Diastolic blood pressure in mmHg. 

 

PUL./min 

 
Pulse per minute. 
 

 

 

 

 

Flashing of the Bluetooth light indicates that the gadget 
is waiting for pairing with the mobile/tab. 

 

Steady Bluetooth light indicates that the gadget is paired 
and ready for the measurement. 

         
      

 

 

Steady green light indicates that the gadget is operating 
in battery mode. 

         
      

 

 

 
Steady red light indicates that the gadget is in the charging 
mode.

 

    

 

 
Symbol for “DISPOSAL” 

    

 

 
Symbol for “KEEP DRY” 

  

 

 
Symbol for “MANUFACTURER” 

  

 

 
Symbol for “MANUFACTURED DATE” 

 

 

 
Symbol for “SERIAL NUMBER” 

Содержание VA 01

Страница 1: ...ONE TOUCH WIRELESS HEALTH TRACKER BODY LIFE TRACKER User Manual Model VA 01 Document No AMI PRD UM B VA01 Version 4 0 Date 08 03 2018...

Страница 2: ...Private Ltd be held liable for any loss expenses or damage of any kind whatsoever whether direct indirect incidental or consequential arising from the design or use of this product or the support mat...

Страница 3: ...ights Reserved American Megatrends India Private Ltd Document History Version Date Comment 1 0 31 12 2015 Initial Release 2 0 23 03 2015 Added battery care section 3 0 31 12 2015 Included FCC statemen...

Страница 4: ...0 1 Blood Pressure measurement with B O L T 12 10 2 Blood Pressure Classification for Adults 13 11 Blood Oxygen Level Measurement Procedures 14 11 1 Blood Oxygen Level measurement with B O L T 14 11 2...

Страница 5: ...ctor in a hospital environment and by users in a home environment 2 Product Description The B O L T VA 01 device is a medical gadget with NiBP Non invasive Blood Pressure Pulse Oximeter SpO2 and Infra...

Страница 6: ...India Private Ltd 3 Package Contents of BOLT VA 01 S No Packing List Quantity 1 Base Unit 1 2 Cuff 1 3 IR Thermometer IRT Probe 1 4 Dust Cover 1 pack 5 SpO2 probe 1 6 Power Adapter 1 7 USB Cable 1 8...

Страница 7: ...nce 4 1 Warning If you encounter any problem while taking blood pressure measurement such as inflation does not stop or air leakage in the cuff remove the cuff or pull out the air tube from the base u...

Страница 8: ...d Lemo connector plug safe and use as per the above instructions to protect the device from dust and to meet the ESD requirements Please do not use the same cuff for patients who are highly infectious...

Страница 9: ...3 Care and Maintenance Store the gadget and the accessories in a clean and safe location Changes or modifications not approved by the manufacturer will void the user warranty Keep the accessories and...

Страница 10: ...of the patient is also required together with the results of any other tests suggested by a doctor 6 Product Features Elegant design enables simple and easy use of the product Multiple Platform Suppo...

Страница 11: ...corner of the home view Note You can also login as a guest user while internet unavailability which might not store the measured vital parameters in the cloud storage space on the measured parameters...

Страница 12: ...r Name and Password which was used for the registration or use Guest login Measuring BP with B O L T 6 On successful login of the B O L T application Select How is my health option to perform Master H...

Страница 13: ...e that the save option is enabled for storing the data in the cloud 10 2 Blood Pressure Classification for Adults The World Health Organization WHO has created the following classification for assessi...

Страница 14: ...with B O L T B O L T enables connecting a SpO2 probe through which the blood oxygen level is measured Connecting SpO2 probe with the gadget Insert the SpO2 connector into the socket firmly as shown be...

Страница 15: ...dings fluctuations may occur below 85 of SpO2 for certain ethnicity group If the SpO2 values are deviated below 70 or above 100 ensure that the user is stable and positions his finger properly as show...

Страница 16: ...erature measurement with B O L T B O L T enables connecting an IR Thermometer probe through which the temperature is measured Connecting IR Thermometer probe with the gadget Insert the IR Thermometer...

Страница 17: ...s mass and height BMI provides a simple numeric measure of a person s thickness or thinness allowing health professionals to discuss overweight and underweight problems more objectively with their pat...

Страница 18: ...level in the mobile application software Even though Over charging is mitigated in the design it s recommended to unplug the power adapter from the power source when the charge level reaches 100 When...

Страница 19: ...Ltd 3 Press and remove the battery cover in the recommended direction as shown below 4 Disconnect the battery pack from the connector and replace with new one 5 Install the battery cover and fasten wi...

Страница 20: ...rnet Data disconnection Enable internet connection through mobile data or Wi Fi and try again Device requests for Bluetooth pairing password Bluetooth pairing permission required Give the password as...

Страница 21: ...t the device doesn t inflate the BP cuff Bluetooth communication error Close the application Restart the B O L T device and restart the entire process again Spo2 probe not connected Spo2 probe connect...

Страница 22: ...icator displays low battery power of the gadget in the mobile device SYS Systolic blood pressure in mmHg DIA Diastolic blood pressure in mmHg PUL min Pulse per minute Flashing of the Bluetooth light i...

Страница 23: ...PEAN CONFORMITY Symbol for Federal Communication Commission Symbol for Read the documentation Symbol for Warning Symbol for Temperature limitation Symbol for Symbol for TYPE BF APPLIED PARTS Cuff only...

Страница 24: ...o 200 BPM Pulse Accuracy 5 Cuff Limb Circumference 22 cm to 42 cm Cuff Size 610 mm 145 mm Cuff Weight 205 Grams IR Thermometer IRT Probe Body Temperature measurement method Tympanic Infrared based Bod...

Страница 25: ...rticular requirements for basic safety and essential performance of pulse oximeter equipment EN 80601 2 30 2010 Particular requirements for basic safety and essential performance of automated non inva...

Страница 26: ...ts are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy And if not installed an...

Страница 27: ...port by calling 1800 200 8001 Enclose the warranty card Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to pre...

Страница 28: ...8 All Rights Reserved American Megatrends India Private Ltd European Representative American Megatrends International GmbH Truderingerstra e Truderinger Strasse 283 81825 M nchen Munich Deutschland Ge...