Secure furring strips to studs in wall.
74.00 O.D.
96.19
6.00
24.00
O.C.
UPRIGHTS
SAMPLE ELEVATION
6.00
34.50
34.50
23.00
74.00 (OVERALL WIDTH)
4.00
4" X .75" FURRING STRIP
Floor
Wall
SYSTEM 1224
FURRING STRIPS
BEFORE YOU BEGIN:
The following instructions will show a three bay
elevation using typical 8' uprights as a sample installation. Although
System 1224 can be secured directly to a suitable substrate wall,
B+N recommends the use of furring strips. Furring strips will insure
a strong and stable installation.
STEP 1:
Determine the overall width of the elevation. This can be
calculated by adding the on-center dimension of the bays plus 1" on
each end. For example a three bay elevation is 24"+24"+24"+1+1"=
74".
STEP 2:
Cut four wood furring strips. Furring strip measurements are
4"H X .75" thick X 74" (length calculated above).
STEP 3:
Locate and mark studs in the wall. Now determine the
starting location of the elevation. The first furring strip will be
installed 6" (recommended) off the floor. Using a level, secure the
furring strip to the wall into the studs.
STEP 4:
Attach the three additional furring strips using the
dimensions shown.
PAGE
2 of 10
10' UPRIGHT
(FLOOR TO WALL SHOWN)
1
2
3
4
5
BAY
1
BAY
2
BAY
3
1
2
3
4
650.593.4127