8
9
1
3
Setup
Operation Instructions
Maintenance & Care
Notice
Cleaning Method
Notice
A damp (non-abrasive) cloth can be used to
clean the unit surface.
Never rinse or soak the HEPA Filter
or NCCO Reactor with water.
Notice
WARNING
Always disconnect the power supply of the
unit before any maintenance or care process
is carried out (except replacing filters).
(Otherwise the unit might still be running
and could cause an electrical shock or injury)
■
It is prohibited to clean the unit with any detergent.
■
If cleaning the unit by using a cloth that is chemically
treated, please read the instructions supplied.
■
During maintenance work, do not touch the
disassembled parts randomly and ensure you do not
stumble over them, thus injuring yourself or damaging
the parts.
■
If the HEPA Filter has not been installed, please do
not operate the unit since this could cause irreversible
damage to the NCCO Reactor.
■
If the HEPA Filter is not replaced periodically
as indicated in instructions, it may seriously affect
the efficiency of the NCCO Reactor.
2
Use a soft brush or light vacuum to
clean the air inlet and air outlet.
Cleaning Pre-filter
Wipe Unit body by soft and dry
cloth.
Available to use water to clean Pre-filter.
Wipe up Filter before reassembling Filter into unit.
Cleaning External Surfaces of Unit Body
Cleaning Air Inlet and Air Outlet
First increase air speed to the highest air speed (10), then long press the
rightmost of the Air Speed Slider for 3 seconds to enter into SS Mode.
It is recommended to select SS mode to treat a seriously contaminated
environment at a short time.
Long press the rightmost of the Air Speed Slider for 3 seconds or press the
ON / OFF Button to turn off unit and then turn on unit agani for turning
back to Air Speed Mode.
Enter Eco Mode: Press the Eco Mode Button to enter into Eco Mode, where
'Eo' displays at the Screen. Under Eco Mode, the unit operates with lower
air speed, weaker noise and dimmer indicators.
Exit Eco Mode: Press the Eco Mode Button again to exit Eco Mode and turn
back to Air Speed Mode. It is recommended to select Eco Mode during
sleep time.
5. TURBO MODE
4. SS MODE
6. FILTER INSTALLATION SUGGESTION
If HEPA Filter or NCCO Reactor has not been properly installed, the Filter
Installation Indicator will flash red and blue alternately, 'EE' will display at
Display Screen, 'Di·Di·Di·Di' sound will be heard from unit and the unit
won't operate.
Proper Operation: Disconnect power supply and open Back Cover to re-install
filters. After properly installing filters, the flashing and 'Di·Di·Di·Di' will
stop, 'EE' will disappear, and the unit start running again.
■ The unit is equipped with a special protection feature: It will stop operating with all indicating lights off for
30mins, after every 8 hours' non-stop operation. 30mins later the unit resume operating automatically. Press
Power Button can awake the unit at any time.
■ Once after the unit runs for 1 minute without receiving any further operation instructions, all indicating lights
and the Fan Speed Display will be dimed, while other functions remained.
To wake up, press any button on the control panel.
ATTENTION