92
Programming
Resolution
Voltage
0.1 V
Phase
0.1 degrees
Frequency
Hz (< 100 Hz)
0.1 Hz (>100 Hz)
Accuracy
Voltage
AC 0.2% + 0.2% of F.S.
DC 0.2% + 0.4% of F.S.
Phase
0.15 %
Frequency
± 1 % (45 Hz to 100 Hz)
Measurement
Resolution
Voltage
0.1 V
Current
0.01 A
Power
0.01 W
Frequency
0.01 Hz (<100Hz)
0.1 Hz (>100Hz)
Accuracy
Voltage
AC 0.25 % + 0.25 % F.S.
DC 0.25 % + 0.5 % F.S.
Current
AC
0.25 % + 0.375 % F.S. (rms)
0.4 % + 0.75 % F.S. (Peak)
0.25 % + 0.25 % F.S. (rms)
0.25% + 0.5 % F.S. (Peak)
DC 0.25 % + 3 % F.S.
0.25 % + 2 % F.S.
Power
1 % of F.S. for frequency
≦
500 Hz
2 % of F.S. for frequency > 500 Hz
Frequency
0.5 %
AC Input
Voltage
190 to 250V
Frequency
47 to 63 Hz
Maximum Power
2500 VA
3800 VA
Maximum Current
13.2 A
20 A
Power Factor
0.98 (typical)
General
Analog
BNC Input
Input Voltage
Range Max.
0 to ± 10 V
Input Impedance 200 kΩ
Bandwidth
1.2 kHz
Storage Memory
10 programs, up to 100 steps total (list mode)
5 memory locations for user-defined waveforms
9 instrument settings
Remote Interface
Analog programming5, USB (USBTMC or virtual com),
RS2325, GPIB, and Ethernet
Command Response Time
50 ms
Protection
OVP, OCP, OPP, OTP
Содержание 9833B
Страница 1: ...1 9830B Series USER MANUAL Model 9832B 9833B High Power Programmable AC Power Sources ...
Страница 10: ...ix 2 Notations TEXT Denotes a softkey TEXT Denotes a front panel key ...
Страница 28: ...15 6 Menu Tree ...
Страница 86: ...73 THD 11 Harmonic 3 weight 21 3 THD 12 Harmonic 3 weight 24 5 ...
Страница 87: ...74 THD 13 Harmonic 2 5 7 8 weight 2 3 9 8 15 8 2 5 THD 14 Harmonic 2 5 7 8 weight 1 15 4 9 7 9 1 25 ...
Страница 88: ...75 THD 15 Harmonic 5 7 weight 2 45 3 95 THD 16 Harmonic 3 5 7 9 weight 11 4 05 2 1 3 ...
Страница 89: ...76 THD 17 Harmonic 3 5 9 weight 7 17 3 42 0 8 THD 18 Harmonic 3 5 9 weight 8 11 3 48 1 ...
Страница 90: ...77 THD 19 Harmonic 3 5 9 weight 9 38 3 44 1 15 THD 20 Harmonic 3 5 7 9 11 weight 2 1 8 1 6 1 23 0 9 ...
Страница 95: ...82 THD 29 Harmonic 3 5 7 9 11 13 15 weight 33 3 20 13 8 10 8 8 5 7 2 5 5 ...
Страница 103: ...90 1 The instrument will show Cal End then press ESC to complete the external voltage calibration ...
Страница 108: ...95 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 2020 B K Precision Corp Printed in Taiwan v101320 ...