1
3
General Information
The B&K Precision 9830B series are low distortion single phase AC power sources delivering a
maximum of 3000 VA, 300 Vrms, 30 Arms /97.5 Apk. The Output frequency is adjustable from
45 Hz to 1200 Hz. All models are capable of outputting AC, DC or AC+DC. Predefined waveforms
include sine, square, clipped sine and THD waveforms. Standard remote interface include
USBVCP and USBTMC-compliant. RS232, LAN, and GPIB interfaces are available to provide
flexibility for remote operation.
Features
Output AC, DC or AC+DC
3-Phase capability using 3 AC sources and the 3-Phase kit (TL983P-KIT)
Built-in power factor correction (PFC) circuit at the AC input
Low harmonic distortion
Power Line Disturbance simulation
Step, pulse and list modes
Adjustable phase angle control
Built-in and user definable waveforms
Digital I/O port for external trigger, remote inhibit, command completion, failure status,
Analog input for external control
Comprehensive protection modes including OVP, OCP, OTP, fan failure, key lock
3.1
Package Contents
Please inspect the instrument mechanically and electrically upon receiving it. Unpack all items
from the shipping carton, and check for any obvious signs of physical damage that may have
occurred during transportation. Report any damage to the shipping agent immediately. Save
the original packing carton for possible future reshipment. Every instrument is shipped with the
following contents:
1 x 9832B or 9833B AC Power Source
1 x AC input power cord
1 x Certificate of calibration
1 x Test report
Verify that all items above are included in the shipping container. If anything is missing, please
contact B&K Precision.
Содержание 9830B Series
Страница 1: ...1 9830B Series USER MANUAL Model 9832B 9833B High Power Programmable AC Power Sources ...
Страница 10: ...ix 2 Notations TEXT Denotes a softkey TEXT Denotes a front panel key ...
Страница 28: ...15 6 Menu Tree ...
Страница 86: ...73 THD 11 Harmonic 3 weight 21 3 THD 12 Harmonic 3 weight 24 5 ...
Страница 87: ...74 THD 13 Harmonic 2 5 7 8 weight 2 3 9 8 15 8 2 5 THD 14 Harmonic 2 5 7 8 weight 1 15 4 9 7 9 1 25 ...
Страница 88: ...75 THD 15 Harmonic 5 7 weight 2 45 3 95 THD 16 Harmonic 3 5 7 9 weight 11 4 05 2 1 3 ...
Страница 89: ...76 THD 17 Harmonic 3 5 9 weight 7 17 3 42 0 8 THD 18 Harmonic 3 5 9 weight 8 11 3 48 1 ...
Страница 90: ...77 THD 19 Harmonic 3 5 9 weight 9 38 3 44 1 15 THD 20 Harmonic 3 5 7 9 11 weight 2 1 8 1 6 1 23 0 9 ...
Страница 95: ...82 THD 29 Harmonic 3 5 7 9 11 13 15 weight 33 3 20 13 8 10 8 8 5 7 2 5 5 ...
Страница 103: ...90 1 The instrument will show Cal End then press ESC to complete the external voltage calibration ...
Страница 108: ...95 22820 Savi Ranch Parkway Yorba Linda CA 92887 www bkprecision com 2020 B K Precision Corp Printed in Taiwan v081720 ...