2. Wipe inside of housing where HydroLock® plate
will sit clean of debris before inserting patented
HydroLock® plate on to junction box. Align
HydroLock® plate with pins in housing and seat
it firmly in place.
Installation
4. Connect OptiLock® assembly to Patented
HydroLock
®
Barrier plate with quick disconnect.
PROJECT:
TYPE:
WIRING DIAGRAM
LINE
COM
GROUND
REMO
TE
TRANSFORMER
GROUND
HYDROL
OCK PL
AT
E
12V
COM
1. Remove temporary cover. Make watertight
connections using waterproof wire connectors
(provided) to leads on the bottom of Patented
HydroLock® Barrier Plate Assembly.
See wiring
diagram.
3. Turn HydroLock®
Barrier Plate clockwise ¼” to
lock.
Patented
HydroLock® Barrier Plate must be
completely seated to ensure proper seal or
water may intrude. This step must be done
as stated or you will void your warranty.
5. Place OptiLock® in HP2 housing and align
keyhole notch under one of (3) #8 screw heads.
Rotate horizontally to desired aiming position,
then tighten (2) #8 Phillips screws using Phillips
screwdriver.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
HP
2
SERIES
Deep Housing - Standard Solid State LED
Installation Instructions
6. Aim vertically by turning the thumbscrew on
OptiLock® assembly.
TECHNOLOGY
with
TECHNOLOGY
7. Remove any dirt or debris in O-ring groove near
top of housing. Place O-Ring inside of groove.
Failure to clean groove of debris will cause
fixture to fail and void product warranty.
8. Install faceplate using 1/8” Allen wrench and
hand-tighten the faceplate screws in a star
pattern to 30 in-lbs. min.
Do not use a power tool to install screws. Do
not exceed 40 in-lbs.
LED - For use with 12VAC
remote transformer or magnetic
transformers only. B-K Lighting cannot
guarantee performance with third party
manufacturers’ transformers.