RELEASE DATE
12-13-16
REFERENCE
NUMBER
INS000933.1
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Finished grade
8 3/4”
2 window
faceplate
shown
Finished grade
8 3/4”
LINE
12V
FIXTURE
COM
Remote
Transformer
COM
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Optical opening on
faceplate will align with
alignment arrows on
temporary cover
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Finished grade
Concrete
Wire nuts must
clear opening
6”
min.
10. Mount faceplate to collar using (2) #6-32
screws (provided) with a 5/64” Allen wrench.
9. Make watertight connections using waterproof
wire connectors (By Others). Insert fixture and
low voltage wire into Power Pipe™.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
MINI-MICRO™ RECESSED UPLIGHT
Surface Mount Installation
LED - For use with 12VAC
remote transformer or magnetic
transformers only. B-K Lighting cannot
guarantee performance with third party
manufacturers’ transformers.
4. Align holes to final installation orientation.
Arrows on temporary cover point towards screw
location on faceplate for alignment purposes.
NOTE: Do not remove temporary cover until
installation of faceplate.
Finished grade
12”
Finished grade
8 3/4”
LINE
12V
FIXTURE
COM
Remote
Transformer
COM
Screws on faceplate will
align with alignment
arrows on temporary
cover
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Stability flange
Rebar or stake (by others)
Pea gravel or sand
Finished grade
Concrete
Finished grade
Concrete
Wire nuts must
clear opening
6”
min.
Finished grade
15”
6. Remove temporary cover and pull out remote
wiring.
2-1/4” O.D.
2-3/4” O.D.
2. Loop minimum of 6” of wiring inside housing to
allow for fixture service.
NOTE:
Do not remove temporary cover!
Finished grade
Wire nuts must
clear opening
6”
min.
Screws on faceplate will
align with alignment
arrows on temporary
cover
7. Access remote wiring inside housing. Make
watertight connections using waterproof wire
connectors (By Others). Wire nuts must clear
opening. Insert fixture, wiring and connections
into housing.
See wiring diagram.
5. Use a silicone based sealant (By Others) between
fixture and mounting surface.
1. Drill 2-1/4” diameter hole into mounting surface
at uplight installation location as per lighting
plan.
Do not exceed surface diameter, installation
relies on surface mount collar resting on surface
grade. Collar diameter is 2-1/4”. Surface mount
flange is 2-3/4” diameter.
Pull secondary wiring from remote driver.
3. Place housing into hole. Surface mount collar
should rest on finished surface grade.
NOTE:
Do not remove temporary cover!
Core Drill Installation Instructions