PROJECT:
TYPE:
Installation Instructions
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASED
12-8-17
REFERENCE
NUMBER
INS-2187-00
Ground
Hot
Neutral
A
B
C
Horizontal
Vertical
1. Install standard 4” octagonal/round recessed
junction box in the final fixture location according
to designed lighting plan.
2. Pull branch circuit wiring and dimming control
wiring necessary for installation (By Others.)
Ground
Hot
Neutral
A
B
C
Horizontal
Vertical
3.
Install universal mounting ring.
IMPORTANT!! Orientation of universal ring will affect orientation of UPM! Take note of
mounting plate holes (indicated with arrows) on the universal ring holes to mount UPM in
correct orientation.
Ground
Hot
Neutral
A
B
C
Horizontal
Vertical
Ground
Hot
Neutral
A
B
C
Horizontal
Vertical
5. Feed branch circuit wiring and dimming control
wiring into UPM housing. Install housing on
CamLock™ at 90° to finished orientation as
shown. (Figure A)
6. Rotate housing 90° counter-clockwise (Figure
B). Tighten set screw with 5/64” Allen wrench on
outside of UPM housing to lock in place.
(Figure C)
7. If UPM housing is not level, remove UPM housing;
loosen but DO NOT REMOVE (2) #8-32 screws
with 9/64” Allen wrench on CamLock™ assembly.
Adjust CamLock™ assembly up to 30° as needed
to level. Tighten the screws and reattach UPM
housing.
Ground
Hot
Neutral
A
B
C
Horizontal
Vertical
4. Feed branch circuit wiring and dimming control
wiring through mounting plate with CamLock™
assembly. Attach mounting plate with supplied
(2) #10-24 stainless steel hex drive fasteners to
universal ring using 1/8” Allen wrench.
8. Attach tether wire under screw head at the base
of the UPM housing. Slowly lower the faceplate
until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
WIRING DIAGRAM
9. Use waterproof wire connectors (By Others) to
connect driver primary leads to branch circuit
wires. Connect incoming ground to ground wire
provided in UPM housing. Connect incoming
dimming control wires to driver dimming
controls See wiring diagram.
Ground
Hot
Neutral
A
B
C
Horizontal
Vertical
10. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening
the (6) #10-24 captive screws evenly using a 1/8”
Allen wrench.
PM3RM ROUND CAMLOCK™
Driver Housing
LINE
Red
FIXTURE
COM
Hydrolock
Plate
Black
GROUND
Driver
White
Black
Green
DIM +
DIM -
Black
White
Hydrolock
Plate
Green
Driver
White
Black
White
Blue
Green
LINE
COM
GROUND
Orange
Orange
Brown
Blue
Black
Gray
FIXTURE
FIXTURE
Green
Green
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
HP2RM
HP2 TR
TMB
PCIII
Generic TR
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
PM3
GROUND IN HOUSING
LINE
Quick
Connect
COM
Driver
FIXTURE
DIM +
DIM -
Quick
Connect
Driver
FIXTURE
DIM +
DIM -
PM3D
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
Fixture
Fixture
PM3RM
GROUND ON PLATE
LINE
COM
Driver
DIM +
DIM -
PCIII
Quick
Connect
FIXTURE
LINE
Red
FIXTURE
COM
Remote
Driver
Black
DIM +
DIM -
MA/AP
GROUND
GROUND IN HOUSING
LINE
COM
Remote
Driver
DIM +
DIM -
DIM +
DIM -
PM3DRM
Fixture
Fixture
Remote
Driver
Fixture
Fixture