RELEASE DATE
11-17-17
REFERENCE
NUMBER
INS-2681-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
HP
2
RM SERIES
23W-34W Remote - Solid State LED
Installation Instructions
PROJECT:
TYPE:
4. Wipe inside of housing where HydroLock® plate
will sit clean of debris before inserting patented
HydroLock® plate on to junction box. Align
HydroLock® plate with pins in housing and seat
it firmly in place.
Installation
6. Connect driver assembly to Patented
HydroLock® Barrier plate with quick disconnects.
WIRING DIAGRAM
LINE
Red
FIXTURE
COM
Hydrolock
Plate
Black
GROUND
Driver
White
Black
Black
White
Hydrolock
Plate
Green
Driver
White
Black
White
Blue
Green
LINE
COM
GROUND
Orange
Orange
Brown
Blue
Black
Gray
FIXTURE
FIXTURE
Green
Green
Green
DIM +
DIM -
DIM +
DIM -
DIM +
DIM -
Hydrolock
Plate
LINE
COM
GROUND
FIXTURE
FIXTURE
DIM +
DIM -
1. Remove temporary cover.
2. Pull primary branch circuit wiring into junction
box.
3. Make watertight connections using waterproof
wire connectors (provided) to leads on the
bottom of Patented HydroLock® Barrier Plate
Assembly. See wiring diagram(s).
5. Turn HydroLock®
Barrier Plate clockwise ¼” to
lock.
Patented HydroLock® Barrier Plate must be
completely seated to ensure proper seal or
water may intrude. This step must be done as
stated or you will void your warranty.
7. Lower driver assembly into HP2 housing.
8. Attach driver assembly to housing by aligning
keyhole notch under one (1) of three (3) #8
screw heads.
For use with 23-34 watt dimming driver.
9. Tighten the Phillips screws to secure driver
plate to housing.