IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

Fixture Relamping

RELEASE DATE

07/11/2023

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

REFERENCE NUMBER

INS-2862-00

1.  Remove faceplate from collar using two (2) #8-32 

flat head screws (included) with a 9/64” allen 

wrench.

2.  Remove fixture from collar.

3.  Loosen two (2) #8-32 screw with a 5/64” allen 

wrench to remove faceplate.

4.   Space three fingers evenly around the optic and 

gently rock optic to remove.  

6.   Disengage LED board and driver assembly. Replace 

with new board and driver assembly.  

7.   Reverse install LED board and driver by carefully  

engaging quick disconnects and inserting into 

fixture body. Secure LED board in place with 

stainless steel screws. Snap optics in place. 

8.  With flat head screw driver rotate dial to desired 

lumen output. Replace fixture in mounting collar.

5.  Use a 5/64” allen wrench to remove two (2) #2-56 

socket head cap screws on LED board, grasp 

LED board and gently pull up to expose quick 

disconnect. 

9.  Mount faceplate to collar using two (2) #8-32 flat 

head screws (included) with a 9/64” allen wrench. 

Do not overtighten.

Standard Installation

ARTISTAR UPLIGHT

SURFACE MOUNT