IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
In-Ground Installation Instructions
RELEASE DATE
07/11/2023
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
REFERENCE NUMBER
INS-2862-00
9. Remove temporary cover and pull out remote
wiring.
Finished grade
Wire nuts must
clear opening
6”
min.
10. Access remote wiring inside housing. Make
watertight connections using waterproof wire
connectors. Wire connectors must clear opening.
Insert fixture, wiring and connections into housing.
See wiring diagram.
HOT
12V
12V
FIXTURE
NEUTRAL
Remote
Transformer
WIRING DIAGRAM
LED - For use with 12VAC LED remote
transformer or magnetic transformers only. B-K
Lighting cannot guarantee performance with
third party manufacturers’ transformers.
8. Fill with soil, then compress. Layer paver sand as
required for paver installation, then install pavers.
Pavers may need to be cut to fit around housing.
11. Mount faceplate to collar using two (2) #8-32 flat
head screws (included) with a 9/64” allen wrench.
Stability Flange
Rebar or Stake (Not Included)
Pea Gravel
Finished Grade
Pavers
Paver Sand
Soil
Standard Installation
ARTISTAR UPLIGHT
SURFACE MOUNT